19. SPECIFICATIONS
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Weighing capacity |
|
| 122 g |
| 220 g |
|
| 320 g | 1220 g |
| 2200 g |
| 3200 g |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Maximum display |
|
| 122.084 g |
| 220.084 g |
|
| 320.084 g | 1220.84 g |
| 2200.84 g |
| 3200.84 g |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Minimum weighing value (1 digit) |
|
|
|
| 0.001 g |
|
|
|
|
| 0.01 g |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Repeatability (Standard deviation) |
|
|
|
| 0.001 g |
|
|
|
|
| 0.01 g |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Linearity |
|
|
|
|
|
|
| ±0.002 g |
|
|
|
|
| ±0.02 g |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Stabilization time (typical at | FAST) |
|
|
|
|
|
|
|
| Approx. 1 second |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Sensitivity drift |
|
|
|
|
|
|
| ±2 ppm/°C |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |||||||||||
| Operating environment |
|
|
|
| 5°C to 40°C (41°F to 104°F) |
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
| 85%RH or less (No condensation) |
|
| ||||||||
|
|
|
|
|
|
|
|
| ||||||||||||
| Display refresh rate |
|
|
| 5 times/second, 10 times/second or 20 times/second |
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| Counting | Minimum unit mass |
|
|
|
| 0.001 g |
|
|
|
|
| 0.01 g |
|
| |||||
| mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Number of samples |
|
|
|
|
| 5, 10, 25, 50 or 100 pieces |
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Percent |
| Minimum 100% reference mass |
|
|
|
| 0.100 g |
|
|
|
|
| 1.00 g |
|
| ||||
| mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Minimum 100% display |
|
| 0.01%, 0.1%, 1% (Depends on the reference mass stored.) |
| ||||||||||||||
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| External calibration weight |
|
| 100 g |
| 200 g |
|
| 300 g | 1000 g |
| 2000 g |
|
| 3000 g |
| ||||
|
|
|
|
|
|
|
| 50 g |
| 100 g |
|
| 200 g | 500 g |
| 1000 g |
|
| 2000 g |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 100 g |
|
|
|
|
| 1000 g |
|
| Weighing pan diameter |
|
|
|
| 130 mm |
|
|
|
|
| 150 mm |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Net weight |
|
|
|
|
|
|
|
|
|
| Approx. 2.5 kg |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||||||||||||
| External dimensions |
|
|
|
| 193 (W) x 262.5 (D) x 84.5 (H) mm |
|
| ||||||||||||
|
|
|
|
|
| |||||||||||||||
| AC adapter |
|
| Confirm that the adapter type is correct for the local voltage and power |
| |||||||||||||||
|
|
|
|
|
|
|
| receptacle type |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||||||||||||
| Power consumption |
|
|
|
| Approx. 11VA (supplied to the AC adapter) |
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Interface |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
60