A&D FX-120i/FX-200i/FX-300i/FX1200i/FX2000i/FX3000i Index Keys and symbols ON/OFF key Sample key

Page 65

Index

 

 

 

Keys and symbols

 

 

ON/OFF key

8

SAMPLE key

8

MODE key

8, 9

CAL key

8, 24, 26

PRINT key

8

RE-ZERO key

7, 8, 12

 

Stabilization indicator

8

 

Interval output mode active indicator ....

8

 

Interval output mode standby indicator ..

8

 

Processing indicator

8

CR

39

LF

39

Space

39

100% reference mass

15

- A -

 

 

 

A&D standard format

33, 37

AC adapter

4

AC adapter ID label

4

ACAI

............................................

14

AD-1683

........................................

6, 59

AD-8121B

44, 48, 59

AD-8920

............................................

59

AD-8922

............................................

59

AK

............................................

52

Animal mode indicator

8

ap fnc

Application

16, 33

ap-b

Auto print difference

32

apf

Application function

16, 33

ap-p

Auto print polarity

32, 48

Application

16, 33

Application function

16, 33

ar-d

Zero after output

32

at-f

Auto feed

32

Auto display-OFF

31, 35

Auto display-ON

31, 35

Auto print difference

32

Auto print mode A

32, 36

Auto print mode B

32, 36

Auto print polarity

32

AVE

Average

18

Average

................................

16, 18, 33

AX-FXi-13

59

- B -

 

 

 

 

ba5fnc

Environment display

.....

11, 31

Baud rate

................................

33, 47, 48

beep

Beep

...................................

31

bep-

HI buzzer

31

bep-

LO buzzer

31

bep-

OK buzzer

31

bp5

Baud rate

33, 48

Breeze break

 

4, 58

btpr

Data bit, parity bit

33, 48

Built-in battery unit

58

- C -

 

 

 

 

Cal e

Calibration weight error

56

-Cal e

Calibration weight error

56

CAL key

..............................................

 

8

Calibration

23, 24, 25, 29, 42, 56, 62

Calibration report

25, 42

Calibration test

 

26, 42

Calibration test report

27, 42

CanCel

............................................

 

18

Capacity indicator

8, 33, 40

Clear

............................................

 

18

Coefficient of variation

16, 18, 33

Command list

 

51

Comparator function

41

Comparator indicators

8

Cond

Condition

31, 34

Counting mode

...................................

13

Cp

Comparator mode

31

Cp fnc

Comparator

31

Cp Hi

Upper limit

31

Cp lo

Lower limit

31

Crlf

Terminator

33, 48

CSV format

 

33, 38

CV

Coefficient of variation

18

- D -

 

 

 

 

Data bits

............................................

 

47

Data format

 

33

Data output mode

32

Data output pause

32

63

Image 65
Contents WM+PD4001199 RI SPage Contents RS-232C Serial Interface MaintenanceConnection to Peripheral Equipment External Dimens IonsIntroduction FeaturesAbout This Manual ComplianceUnpacking Unpacking the BalanceInstalling the Balance During Use PrecautionsBefore Use After Use Power SupplyDisplay symbols Display Symbols and Key OperationKey operation Function TableUnits Weighing UnitsCapacity RE-ZERO Storing UnitsSample Weighing Basic Operation Gram ModeStoring a sample unit mass Counting Mode PCSSelecting the counting mode Counting operation Counting mode using the Acai functionSelecting the percent mode Percent Mode %Storing the 100% reference mass Reading the percentageGetting Started Statistical Calculation ModeSelecting the unit Selecting the statistical items to outputMode PrintOutputting the statistical results Clearing the statistical data Deleting the latest dataEnabling the statistical calculation mode Statistical Calculation Mode Example of UseReturning to the weighing mode Changing the function tableUsing The Statistical Calculation Mode Operation Response AdjustmentFast MID SlowCalibration Calibration ModeTerms DisplayCAL Calibration Using an External WeightEnd Calibration Test Using an External Weight Glp1 Permit or Inhibit Function Switch and InitializationSwitches Operation Initializing the Balance Structure and Sequence of the Function Table Function TableDisplay and Keys ExampleDetails of the Function Table Auto print polarity Data output modeAuto print difference Data outputAK, Error code TimeoutMode output items Factory settingsDescription of the Class Environment, Display Hold function Hold Animal weighing modeCondition Cond CondTrc Zero tracking trcDisplay refresh rate 5pd Decimal point pntDescription of the Item Data Output Mode Description of the Item Data Format Interval output modeStandard format DP Dump print format 5if typeMT format KF format 5if typeNU numerical format CSV format 5if typeData Format Examples Description of the Item Application Function Capacity indicator apfStatistical calculation mode apf Comparator Function Setting exampleID Number and GLP Report Setting the ID NumberGLP Report Display character setCalibration test report using an external weight Calibration report using an external weightTitle block and end block Underhook PROGRAMMABLE-UNIT Sub 9-pin assignments RS-232C Serial InterfaceOFF Connection to Peripheral EquipmentConnection to the AD-8121B Printer Connection to a Computer Using Windows Communication Tools WinCTRsCom RsKeyUsing the WinCT software, the balance can do the following Command List CommandsCommands to query weight data Commands to control the balanceAcknowledge Code and Error Codes Settings Related to RS-232C Maintenance Checking that the balance performs properly TroubleshootingChecking the Balance Performance and Environment Error Codes Asking For Repair Options Page FX-300i SpecificationsFX-1200i / 2000i External DimensionsFX-120i / 200i GLP TERMS/INDEXStabilization indicator Index Keys and symbols ON/OFF key Sample keyCapacity indicator Condition Counting modeDigit 31, 35 NET indicatorFXi-02 FXi-08 FXi-09 FXi-10 FXi-11 GLP output 23, 25, 26, 32Parity Pcs Stability band width Stop bit Stream modePermit PrinterMemo Memo Memo Page Korea Limited German Scales Office