A&D FX-120i/FX-200i/FX-300i/FX1200i/FX2000i/FX3000i Digit 31, 35, GLP output 23, 25, 26, 32

Page 66

DC static eliminator

59

DCE

......................................

47, 49

Decimal point

31, 35

Digit

................................

31, 35, 62

Display at start

31

Display refresh rate

31, 35

dout

Data output

32

DP format

33, 37

DTE

............................................

47

- E -

 

 

-e

............................................

56

EC, E00

............................................

57

EC, E01

............................................

57

EC, E02

............................................

57

EC, E03

............................................

57

EC, E04

............................................

57

EC, E06

............................................

57

EC, E07

............................................

57

EC, E11

............................................

56

EC, E20

............................................

56

EC, E21

............................................

56

End block

............................................

44

erCd

Error code

33

error1

............................................

56

error2

............................................

56

Ethernet interface

58

External dimensions

60, 61

- F -

 

 

FAST

............................................

22

Function table

30

FXi-02

............................................

58

FXi-08

............................................

58

FXi-09

............................................

58

FXi-10

............................................

58

FXi-11

............................................

58

- G -

 

 

GLP

............................................

42

GLP output

23, 25, 26, 32, 42

Grounding terminal

4

- H -

 

 

Hold

Hold function

31, 34

Hold function

31, 34

- I -

 

 

 

ID number

42

info

GLP output

32

Inhibit

...........................................

28

Initializing the balance

29

int

Interval time

32

Interval output mode

32, 37

Interval output mode active indicator

... 8

Interval output mode standby indicator

... 8

Interval time

32

- K -

 

 

 

Key mode

32, 36

Key mode B

32, 36

Key mode C

32, 36

KF format

33, 38

- L -

 

 

 

Leveling foot

4

Linearity

60

lo

...........................................

56

Lower limit value

41

- M -

 

 

 

Main unit cover

4, 59

MAX

Maximum

18

Maximum

16, 18, 33

Maximum display

60

MID.

........................................... 22

MIN

Manimum

18

Minimum

16, 18, 33

Minimum 100% reference mass

60

Minimum unit mass

60

Minimum weighing value

60

MODE key

8, 9, 11

MT format

33, 38

- N -

 

 

 

NET indicator

8

NU format

33, 38

64

Image 66
Contents RI S WM+PD4001199Page Contents Connection to Peripheral Equipment MaintenanceRS-232C Serial Interface External Dimens IonsAbout This Manual FeaturesIntroduction ComplianceUnpacking the Balance UnpackingInstalling the Balance Precautions Before UseDuring Use Power Supply After UseKey operation Display Symbols and Key OperationDisplay symbols Function TableWeighing Units UnitsCapacity Storing Units SampleRE-ZERO Basic Operation Gram Mode WeighingCounting Mode PCS Selecting the counting modeStoring a sample unit mass Counting mode using the Acai function Counting operationStoring the 100% reference mass Percent Mode %Selecting the percent mode Reading the percentageStatistical Calculation Mode Getting StartedMode Selecting the statistical items to outputSelecting the unit PrintOutputting the statistical results Deleting the latest data Clearing the statistical dataReturning to the weighing mode Statistical Calculation Mode Example of UseEnabling the statistical calculation mode Changing the function tableUsing The Statistical Calculation Mode Fast Response AdjustmentOperation MID SlowTerms Calibration ModeCalibration DisplayCalibration Using an External Weight CALEnd Calibration Test Using an External Weight Glp1 Function Switch and Initialization Switches OperationPermit or Inhibit Initializing the Balance Display and Keys Function TableStructure and Sequence of the Function Table ExampleDetails of the Function Table Auto print difference Data output modeAuto print polarity Data outputMode output items TimeoutAK, Error code Factory settingsCondition Cond Hold function Hold Animal weighing modeDescription of the Class Environment, Display CondDisplay refresh rate 5pd Zero tracking trcTrc Decimal point pntDescription of the Item Data Output Mode Standard format Interval output modeDescription of the Item Data Format DP Dump print format 5if typeNU numerical format KF format 5if typeMT format CSV format 5if typeData Format Examples Capacity indicator apf Statistical calculation mode apfDescription of the Item Application Function Setting example Comparator FunctionGLP Report Setting the ID NumberID Number and GLP Report Display character setCalibration report using an external weight Calibration test report using an external weightTitle block and end block Underhook PROGRAMMABLE-UNIT RS-232C Serial Interface Sub 9-pin assignmentsConnection to Peripheral Equipment Connection to the AD-8121B PrinterOFF RsCom Using Windows Communication Tools WinCTConnection to a Computer RsKeyUsing the WinCT software, the balance can do the following Commands to query weight data CommandsCommand List Commands to control the balanceAcknowledge Code and Error Codes Settings Related to RS-232C Maintenance Troubleshooting Checking the Balance Performance and EnvironmentChecking that the balance performs properly Error Codes Asking For Repair Options Page Specifications FX-300iExternal Dimensions FX-120i / 200iFX-1200i / 2000i TERMS/INDEX GLPCapacity indicator Index Keys and symbols ON/OFF key Sample keyStabilization indicator Condition Counting modeFXi-02 FXi-08 FXi-09 FXi-10 FXi-11 NET indicatorDigit 31, 35 GLP output 23, 25, 26, 32Permit Stability band width Stop bit Stream modeParity Pcs PrinterMemo Memo Memo Page German Scales Office Korea Limited