A&D FX-120i/FX-200i/FX-300i/FX1200i/FX2000i/FX3000i Introduction, About This Manual, Features

Page 5

1. INTRODUCTION

This manual describes how the FX-i series balance works and how to get the most out of it in terms of performance.

Read this manual thoroughly before using the balance and keep it at hand for future reference.

1-1 About This Manual

This manual consists of the following five parts:

Basic operation

Describes precautions on handling the balance, balance

 

construction and basic balance operation.

Adapting to the environment....

Describes response adjustment and calibration.

Functions

Describes various functions of the balance.

RS-232C serial interface

Describes the interface which transmits data and controls the balance.

Maintenance

Describes maintenance, error codes, troubleshooting,

 

specifications and options.

1-2 Features

Compact general-purpose balance, can be installed almost anywhere.

Casing construction, strong protection against dust and moisture.

Stabilization time of one second. When FAST is selected for the response rate, a stabilization time of one second, to read a displayed value after a sample is placed on the pan, has been achieved.

Multiple weighing units with most of the common units used around the world.

Standard RS-232C serial interface to communicate with a computer and to output the Good Laboratory Practice (GLP) data

Statistical calculation mode to statistically calculate the weight data, and display or output the sum, maximum, minimum, range (maximum-minimum), average, standard deviation and coefficient of variation.

Comparator Indicators, displaying the comparison results.

Hold Function, provided for weighing a moving object such as an animal. Breeze break, provided for the FX-120i/200i/300i, for more accurate weighing. Underhook, provided for suspended weighing.

As options, the USB interface (FXi-02), the Ethernet interface (Fxi-08) and the built-in battery unit (Fxi-09) are available.

1-3 Compliance

Compliance with FCC Rules

Please note that this device generates, uses and can radiate radio frequency energy. This device has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable protection against interference when this device is operated in a commercial environment. If this unit is operated in a residential area, it may cause some interference and under these circumstances the user would be required to take, at his own expense, whatever measures are necessary to eliminate the interference.

(FCC = Federal Communications Commission in the U.S.A.)

3

Image 5
Contents WM+PD4001199 RI SPage Contents RS-232C Serial Interface MaintenanceConnection to Peripheral Equipment External Dimens IonsIntroduction FeaturesAbout This Manual ComplianceUnpacking Unpacking the BalanceInstalling the Balance During Use PrecautionsBefore Use After Use Power SupplyDisplay symbols Display Symbols and Key OperationKey operation Function TableUnits Weighing UnitsCapacity RE-ZERO Storing UnitsSample Weighing Basic Operation Gram ModeStoring a sample unit mass Counting Mode PCSSelecting the counting mode Counting operation Counting mode using the Acai functionSelecting the percent mode Percent Mode %Storing the 100% reference mass Reading the percentageGetting Started Statistical Calculation ModeSelecting the unit Selecting the statistical items to outputMode PrintOutputting the statistical results Clearing the statistical data Deleting the latest dataEnabling the statistical calculation mode Statistical Calculation Mode Example of UseReturning to the weighing mode Changing the function tableUsing The Statistical Calculation Mode Operation Response AdjustmentFast MID SlowCalibration Calibration ModeTerms DisplayCAL Calibration Using an External WeightEnd Calibration Test Using an External Weight Glp1 Permit or Inhibit Function Switch and InitializationSwitches Operation Initializing the Balance Structure and Sequence of the Function Table Function TableDisplay and Keys ExampleDetails of the Function Table Auto print polarity Data output modeAuto print difference Data outputAK, Error code TimeoutMode output items Factory settingsDescription of the Class Environment, Display Hold function Hold Animal weighing modeCondition Cond CondTrc Zero tracking trcDisplay refresh rate 5pd Decimal point pntDescription of the Item Data Output Mode Description of the Item Data Format Interval output modeStandard format DP Dump print format 5if typeMT format KF format 5if typeNU numerical format CSV format 5if typeData Format Examples Description of the Item Application Function Capacity indicator apfStatistical calculation mode apf Comparator Function Setting exampleID Number and GLP Report Setting the ID NumberGLP Report Display character setCalibration test report using an external weight Calibration report using an external weightTitle block and end block Underhook PROGRAMMABLE-UNIT Sub 9-pin assignments RS-232C Serial InterfaceOFF Connection to Peripheral EquipmentConnection to the AD-8121B Printer Connection to a Computer Using Windows Communication Tools WinCTRsCom RsKeyUsing the WinCT software, the balance can do the following Command List CommandsCommands to query weight data Commands to control the balanceAcknowledge Code and Error Codes Settings Related to RS-232C Maintenance Checking that the balance performs properly TroubleshootingChecking the Balance Performance and Environment Error Codes Asking For Repair Options Page FX-300i SpecificationsFX-1200i / 2000i External DimensionsFX-120i / 200i GLP TERMS/INDEXStabilization indicator Index Keys and symbols ON/OFF key Sample keyCapacity indicator Condition Counting modeDigit 31, 35 NET indicatorFXi-02 FXi-08 FXi-09 FXi-10 FXi-11 GLP output 23, 25, 26, 32Parity Pcs Stability band width Stop bit Stream modePermit PrinterMemo Memo Memo Page Korea Limited German Scales Office