A&D FX-120i/FX-200i/FX-300i/FX1200i/FX2000i/FX3000i KF format 5if type, MT format

Page 40

KF format

5if type 2

This is the Karl-Fischer moisture meter format and is used when the peripheral equipment can only communicate using this format.

￿This format consists of fourteen characters excluding the terminator.

￿This format has no header characters.

￿The polarity sign is placed before the data, with spaces in place of leading zeros, if the data is not zero or overloaded.

￿This format outputs the unit only for a stable value.

MT format

5if type 3

￿A header of two characters indicates the balance condition.

￿The polarity sign is used only for negative data.

￿The weight data uses spaces in place of the leading zeros.

￿The character length of this format changes dependent upon the unit

NU (numerical) format

5if type 4

This format outputs only numerical data.

￿This format consists of nine characters excluding the terminator.

￿The polarity sign is placed before the data with the leading zeros. If the data is zero, the plus sign is used.

CSV format 5if type 5

￿Separates the data of A&D standard format and the unit by a comma (,).

￿Outputs the unit even when the data is overloaded.

38

Image 40
Contents RI S WM+PD4001199Page Contents Maintenance RS-232C Serial InterfaceConnection to Peripheral Equipment External Dimens IonsFeatures IntroductionAbout This Manual ComplianceUnpacking the Balance UnpackingInstalling the Balance Before Use PrecautionsDuring Use Power Supply After UseDisplay Symbols and Key Operation Display symbolsKey operation Function TableWeighing Units UnitsCapacity Sample Storing UnitsRE-ZERO Basic Operation Gram Mode WeighingSelecting the counting mode Counting Mode PCSStoring a sample unit mass Counting mode using the Acai function Counting operationPercent Mode % Selecting the percent modeStoring the 100% reference mass Reading the percentageStatistical Calculation Mode Getting StartedSelecting the statistical items to output Selecting the unitMode PrintOutputting the statistical results Deleting the latest data Clearing the statistical dataStatistical Calculation Mode Example of Use Enabling the statistical calculation modeReturning to the weighing mode Changing the function tableUsing The Statistical Calculation Mode Response Adjustment OperationFast MID SlowCalibration Mode CalibrationTerms DisplayCalibration Using an External Weight CALEnd Calibration Test Using an External Weight Glp1 Switches Operation Function Switch and InitializationPermit or Inhibit Initializing the Balance Function Table Structure and Sequence of the Function TableDisplay and Keys ExampleDetails of the Function Table Data output mode Auto print polarityAuto print difference Data outputTimeout AK, Error codeMode output items Factory settingsHold function Hold Animal weighing mode Description of the Class Environment, DisplayCondition Cond CondZero tracking trc TrcDisplay refresh rate 5pd Decimal point pntDescription of the Item Data Output Mode Interval output mode Description of the Item Data FormatStandard format DP Dump print format 5if typeKF format 5if type MT formatNU numerical format CSV format 5if typeData Format Examples Statistical calculation mode apf Capacity indicator apfDescription of the Item Application Function Setting example Comparator FunctionSetting the ID Number ID Number and GLP ReportGLP Report Display character setCalibration report using an external weight Calibration test report using an external weightTitle block and end block Underhook PROGRAMMABLE-UNIT RS-232C Serial Interface Sub 9-pin assignmentsConnection to the AD-8121B Printer Connection to Peripheral EquipmentOFF Using Windows Communication Tools WinCT Connection to a ComputerRsCom RsKeyUsing the WinCT software, the balance can do the following Commands Command ListCommands to query weight data Commands to control the balanceAcknowledge Code and Error Codes Settings Related to RS-232C Maintenance Checking the Balance Performance and Environment TroubleshootingChecking that the balance performs properly Error Codes Asking For Repair Options Page Specifications FX-300iFX-120i / 200i External DimensionsFX-1200i / 2000i TERMS/INDEX GLPIndex Keys and symbols ON/OFF key Sample key Stabilization indicatorCapacity indicator Condition Counting modeNET indicator Digit 31, 35FXi-02 FXi-08 FXi-09 FXi-10 FXi-11 GLP output 23, 25, 26, 32Stability band width Stop bit Stream mode Parity PcsPermit PrinterMemo Memo Memo Page German Scales Office Korea Limited