PURGING AND PRIMING
PURGING AND PRIMING THE PUMP
1. Make sure the inlet filter is in | Tab | |
place inside the hopper. If it | ||
| ||
is not, snap in place as |
| |
shown. |
|
2. Push the tab on top of the filter down once. This will ensure proper operation of the inlet valve.
3. Pull the return tube from the
hopper and hold it over a waste container.
4. Turn the PRIME/SPRAY
knob to PRIME. | PRIME | SPRAY |
|
|
5.Plug in the sprayer, and move the ON/OFF switch to the ON position.
l
Any fluids remaining in the pump and the return tube will flow out of the return tube. Let the pump run until no fluid is coming from the return tube.
6.Switch the pump to OFF. Remove the return
tube from the waste container and secure it to the hopper.
O
Fill line
7. Fill your hopper with the material you plan to spray. Do not exceed the fill line as shown. Replace the hopper lid.
8. Leave the PRIME/SPRAY |
|
|
|
knob on PRIME and switch |
| SPRAY | l |
and make sure that material | PRIME | ||
your unit ON once more |
|
|
|
is flowing from the return |
|
|
|
tube. |
|
|
|
Your sprayer is now purged. Move to Purging and Priming the Spray Hose.
PURGING AND PRIMING THE SPRAY HOSE
1. Unlock the spray gun and turn |
|
|
the PRIME/SPRAY knob to |
|
|
PRIME. | PRIME | SPRAY |
Your spray tip SHOULD | ||
NOT be attached to your |
|
|
spray gun when purging |
|
|
your spray hose. |
|
|
2. Trigger and HOLD the spray |
|
|
gun into a waste container |
|
|
(see warnings below). |
|
|
|
| l |
3. While holding the trigger, |
|
|
switch the pump ON. |
|
|
4. While holding the trigger, turn |
| SPRAY |
the PRIME/SPRAY knob to |
| |
SPRAY. Hold the trigger until |
|
|
all air, water, or solvent is |
|
|
purged from the spray hose |
| PRIME |
and paint is flowing freely (read |
|
|
warnings below). |
|
|
WARNING
Keep hands clear from fluid stream.
WARNING
Using a metal container, ground the gun by holding it against the edge of the
container while flushing. Failure to do so may lead to a static electric discharge which may cause a fire.
If the PRIME/SPRAY knob is still on SPRAY, there will be high pressure in the hose and spray gun until the PRIME/SPRAY knob is turned to PRIME.
5.Release trigger, turn the PRIME/SPRAY knob to PRIME
and turn pump OFF . PRIME SPRAY O
6.Trigger the gun into the waste container once more to be sure that no pressure is left in the hose.
7.Lock the spray gun off.
8.Thread the spray tip assembly onto the gun. Tighten by hand.
Begin |
| to achieve |
| ||
tightening |
| the desired |
the tip at |
| spray angle |
this angle |
| when tight. |
Your hose is now purged and primed.
English | Customer Service: | © 2003 Wagner Spray Tech - All rights reserved. |
|
|
|