SPECIFICATIONS / MAINTENANCE
PRODUCT SPECIFICATIONS
AC Frequency: | . . . . . . . . . . . . . . . . . . 60Hz | . . . . . . . . 80 psi (5.6 bars) | |
Rated AC Voltage: | . . . . . 120 Volts, single phase | Cut/Out Pressure Setting: | . . . . . . . 125 PSI (8.7 bars) |
Running Horsepower: | . . . . . . . . . . . . . . . . . 1.2 HP | Tank capacity: | . . . . . . . 6 Gallons (22.5 L) |
Pump Type: | Oil Lubricated Direct Drive | Tank Style: | . . . . . Flat, single (Pancake) |
Lubricant: | . . . . . . SAE 5W50 Synthetic | Recommended Air Hose Size: . . . . | . . . . . 3/8 inch ID (14mm) |
Oil Capacity: | . . . . . . . . 7.168 oz. (200ml) | Air Fittings: | . . . . . . . . . . 1/4 inch NPT |
Air Delivery: |
| Quick Connect Fitting Type: | . . . . . . . . . . . . . . . . . . . I/M |
At 40 psi | . . . . . . . . . . . . . . . . 4.9 CFM | Operating Temperature Range: . . . | 32° to 95°F (0° to + 35°C) |
At 90 psi | . . . . . . . . . . . . . . . . 3.6 CFM | Shipping Weight: | . . . . . . . . . 60lbs. (27.3 Kg) |
MAINTENANCE
To ensure efficient operation and longer life of the air compressor, prepare and follow a routine maintenance schedule.The routine described in this section is intended for an air compressor used under normal daily working conditions. If necessary, modify the schedule to suit the conditions under which you use your compressor. Modifications will depend upon hours of operation and
working environment. Operating air compressors in extremely dirty or hostile environments will require more frequent maintenance checks.
NOTE: See FEATURES AND CONTROLS and OPERATION for control locations.
Follow the hourly or calendar intervals, whichever occurs first:
Maintenance |
|
|
|
|
| Service Dates | |
Schedule |
|
| Service Intervals |
| Fill in as you complete | ||
|
|
|
|
|
| regular service | |
|
|
|
|
|
| ||
Maintenance Task | Daily | Weekly | Every 50 Hours | Every 100 Hours |
|
| |
|
|
| or Yearly |
| or Yearly |
|
|
Inspect Safety Valve | X |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Inspect Fittings/Valves | X |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Inspect Oil Level |
| X |
|
|
|
|
|
|
|
|
|
|
|
|
|
Clean Unit |
| X |
|
|
|
|
|
|
|
|
|
|
|
|
|
Inspect and Clean Air |
|
| X |
|
|
|
|
Filter |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Inspect Pump Oil |
|
|
|
| X* |
|
|
|
|
|
|
|
|
|
|
Inspect Intake and |
|
|
|
| X** |
|
|
Exhaust Valves |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Inspect Safety Labels |
|
|
|
| X*** |
|
|
|
|
|
|
|
|
|
|
*Change oil after first 100 hours of operation, then every 300 hours thereafter
**Return unit to approved repair center annual for inspection and service
***Inspect annually, replace as necessary
11