TROUBLESHOOTING
PROBLEM | CAUSE | CORRECTION | ||
|
|
|
|
|
| 1. | Prolonged excessive use of air. | 1. | Decrease amount of air used. |
| 2. | Compressor is not large enough for air | 2. | Check the accessory requirement. If it is |
|
| requirement. |
| higher than the CFM or pressure supplied by |
Compressor is not |
|
|
| your air compressor, you need a larger |
|
|
| capacity air compressor. | |
supplying enough air to |
|
|
| |
|
|
|
| |
operate accessories. | 3. | Hole in hose. | 3. | Inspect and replace if required. |
| 4. | Check Valve restricted or leaks air. | 4. | Contact trained service technician. |
| 5. | Restricted air intake filter. | 5. | Clean or replace air intake filter |
|
|
|
| (see page 13). |
|
|
|
|
|
| 1. | Motor Overload Protector switch has | 1. | Let motor cool for 15 minutes. Press RESET |
|
| tripped. | ||
|
|
| to reset Overload Protector switch. | |
| 2. | Tank pressure exceeds Pressure Switch |
| |
| 2. | Motor will start automatically when tank | ||
|
| |||
|
|
| pressure drops below | |
|
|
|
| |
| 3. | Loose electrical connections. |
| setting. |
| 3. | Contact trained service technician. | ||
|
|
| ||
| 4. | Possible defective motor or starting | 4. | Contact trained service technician. |
|
| capacitor. | ||
|
|
|
| |
| 5. | Pressure Release Valve on Pressure | 5. | Drain pressure by setting ON - OFF Switch |
|
| Switch has not unloaded head pressure. | ||
|
|
|
| to OFF. If the Pressure Release Valve does |
Motor will not run. |
|
|
| not open, contact trained service technician. |
| 6. | Fuse blown, circuit breaker tripped. | 6A. | Check fuse box for blown fuse and replace as |
|
| necessary. Reset circuit breaker. DO NOT use | ||
|
|
|
| |
|
|
|
| a fuse or circuit breaker with higher rating |
|
|
|
| than that specified for that branch circuit. |
|
|
| B. | Check for proper fuse. Use a time delay fuse. |
|
|
| C. Check for low voltage conditions and/or | |
|
|
|
| proper extension cord. |
|
|
| D. Disconnect all other electrical loads from | |
|
|
|
| circuit used by air compressor OR operate |
|
|
|
| air compressor on dedicated branch circuit. |
|
|
|
| Contact trained service technician. |
|
|
|
|
|