Briggs & Stratton 074000 Compressor is not, Supplying enough air to Operate accessories

Page 17

TROUBLESHOOTING

PROBLEM

CAUSE

CORRECTION

 

 

 

 

 

 

1.

Prolonged excessive use of air.

1.

Decrease amount of air used.

 

2.

Compressor is not large enough for air

2.

Check the accessory requirement. If it is

 

 

requirement.

 

higher than the CFM or pressure supplied by

Compressor is not

 

 

 

your air compressor, you need a larger

 

 

 

capacity air compressor.

supplying enough air to

 

 

 

 

 

 

 

operate accessories.

3.

Hole in hose.

3.

Inspect and replace if required.

 

4.

Check Valve restricted or leaks air.

4.

Contact trained service technician.

 

5.

Restricted air intake filter.

5.

Clean or replace air intake filter

 

 

 

 

(see page 13).

 

 

 

 

 

 

1.

Motor Overload Protector switch has

1.

Let motor cool for 15 minutes. Press RESET

 

 

tripped.

 

 

 

to reset Overload Protector switch.

 

2.

Tank pressure exceeds Pressure Switch

 

 

2.

Motor will start automatically when tank

 

 

“cut-in” pressure.

 

 

 

pressure drops below “cut-in” pressure

 

 

 

 

 

3.

Loose electrical connections.

 

setting.

 

3.

Contact trained service technician.

 

 

 

 

4.

Possible defective motor or starting

4.

Contact trained service technician.

 

 

capacitor.

 

 

 

 

 

5.

Pressure Release Valve on Pressure

5.

Drain pressure by setting ON - OFF Switch

 

 

Switch has not unloaded head pressure.

 

 

 

 

to OFF. If the Pressure Release Valve does

Motor will not run.

 

 

 

not open, contact trained service technician.

 

6.

Fuse blown, circuit breaker tripped.

6A.

Check fuse box for blown fuse and replace as

 

 

necessary. Reset circuit breaker. DO NOT use

 

 

 

 

 

 

 

 

a fuse or circuit breaker with higher rating

 

 

 

 

than that specified for that branch circuit.

 

 

 

B.

Check for proper fuse. Use a time delay fuse.

 

 

 

C. Check for low voltage conditions and/or

 

 

 

 

proper extension cord.

 

 

 

D. Disconnect all other electrical loads from

 

 

 

 

circuit used by air compressor OR operate

 

 

 

 

air compressor on dedicated branch circuit.

 

 

 

 

Contact trained service technician.

 

 

 

 

 

17

Image 17
Contents Call Helpline Appelez Ligne dassistance Llame Línea Directa Operator’s Manual Manuel d’utilisation Manual del OperarioEquipment Description Table of ContentsSafety Rules Make this manual available to other users of this equipment Safety RulesStay Clear Compressor can start any time when pluggedUnpacking AssemblyCarton Contents Quick Connect Fitting Connect air tools here Features and ControlsFeatures and Controls Operation Break-In ProcedureAdd Oil OperationGrounding Instructions Air Compressor Operating LocationStarting Your Air Compressor Pressure Control KnobExtension Cords Stopping Your Air CompressorCompressor Operation Overload Protection ResetMaintenance Product SpecificationsSpecifications / Maintenance Maintenance Service Dates Schedule Service IntervalsMaintenance Inspect Safety ValveInspect Quick Connect Fitting and Tank Drain Valve Inspect / Change Pump OilGeneral Maintenance Cleaning UnitInspect / Clean Air Filter Inspect Pump Intake and Exhaust Valves Inspect Safety LabelsStorage StorageBefore You Call TroubleshootingTroubleshooting Motor will not run Supplying enough air to Operate accessoriesCompressor is not Glossary GlossaryLimited Warranty Description DE L Équipement Table DES MatièresRègles DE Sécurité Description / Règles DE SécuritéRègles DE Sécurité AvertissementÉLOIGNEZ-VOUS Mise EN GardeAssemblage AssemblageContenu de la boîte DéballageSoupape de relâchement de surpression non illustrée Fonctions ET CommandesFonctions ET Commandes Ajoutez de l’huile OpérationProcédure de rodage OpérationDirectives de mise à la terre Emplacement du compresseur d’air lors de l’utilisationDémarrage de votre compresseur d’air ’UTILISEZ PAS UN Adaptateur DE Mise À LA TerreRallonges Arrêt de votre compresseur d’airFermez le robinet de vidange Remarque Évitez d’utiliser des rallongesRéarmement du protecteur de surcharge Utilisation du compresseurBouton de RéarmementEntretien SpécificationsSpécifications / Entretien Fréquence C.A HzVérifiez la soupape de sûreté EntretienVérifiez/changez l’huile de la pompe Vérification du niveau d’huileEntretien général Nettoyage de l’unitéVérifiez/nettoyez le filtre à air Entretien / Entreposage EntreposageVérifiez les étiquettes de sécurité Remarque Remplacez le filtre s’il est extrêmement saleDépannage DépannageAvant de nous contacter Le moteur ne fonctionne pas Le compresseur ne fournit pasSuffisamment d’air pour le Glossaire GlossaireRemarques RemarquesPériode DE Garantie Descripción DEL Equipo Tabla DE ContenidosReglas DE Seguridad Descripción Y Reglas DE SeguridadReglas DE Seguridad AdvertenciaManténgase Alejado PrecauciónMontaje MontajeContenido de la caja DesembalajeCaracterísticas Y Mandos Características Y MandosAcoplamiento para conector rápido Permiten conectar Bomba del compresor de aire La bomba comprime el aire enAñadir aceite OperaciónProcedimiento de preparación para el uso inicial OperaciónInstrucciones de conexión a tierra Colocación del compresorPuesta en marcha del compresor de aire No Utilice UN Adaptador DE Conexión a TierraNota No utilice cables prolongadores Parada del compresor de aireCables prolongadores Rearme de la protección contra sobrecarga Botón ResetUso del compresor Especificaciones / Mantenimiento EspecificacionesMantenimiento Inspeccione la válvula de seguridad MantenimientoInspeccione / cambie el aceite de la bomba Comprobación del nivel de aceiteMantenimiento general Limpieza de la unidadInspeccione / limpie el filtro de aire Nota Sustituya el elemento filtrante si está muy sucio Inspeccione las válvulas de admisión y escape de la bombaInspeccione las etiquetas de seguridad Almacenamiento AlmacenamientoAntes de llamar Diagnositicos DE AveríasDiagnositicos DE Averías Suficiente para accionar los El compresor no suministra aireAccesorios El motor no funcionaGlosario GlosarioNotas NotasPeríodo DE Garantía