Briggs & Stratton 074000 Table of Contents, Equipment Description, Safety Rules

Page 2

DESCRIPTION / SAFETY RULES

SAVE THESE INSTRUCTIONS

TABLE OF CONTENTS

Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4

Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Features and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-14

Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Espanõl. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

EQUIPMENT DESCRIPTION

This manual contains operation and maintenance information for a single stage air compressor that produces 4.9 CFM at 40 PSI (2.8 bars) and 3.6 CFM at 90 PSI (6.2 bars) using a

120 Volt A.C. electric motor.This high quality system features a direct drive oil lube pump with cast iron sleeve, an easy start valve, and a motor overload protection feature with manual restart.

Every effort has been made to ensure that information in this manual is accurate and current. However, we reserve the right to change, alter or otherwise improve the product and this document at any time without prior notice.

Statement of Use

This air compressor has been manufactured to provide an adequate volume of compressed air for operating a variety of light-duty air tools (hand grinders, nailers, ratchets, or staplers), spraying equipment, and inflators requiring less than

4.9CFM air flow for operation. Operate this compressor ONLY in an ambient temperature range from 32° to 95°F (0° to + 35°C).This compressor is designed for a maximum of 70% duty per hour at full load.

Copyright © 2005 Briggs & Stratton Power Products Group, LLC. All rights reserved. No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs & Stratton Power Products Group, LLC.

SAFETY RULES

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

The safety alert symbol () is used with a signal word (DANGER, CAUTION,WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury.WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when not used with the safety alert symbol (), indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.

Hazard Symbols and Meanings

Air Injection

Auto-start

Compressed Air

Electrical Shock

Explosion

Fire

Flying Objects

Hot Surface

Inhalation

2

Image 2
Contents Operator’s Manual Manuel d’utilisation Manual del Operario Call Helpline Appelez Ligne dassistance Llame Línea DirectaEquipment Description Table of ContentsSafety Rules Safety Rules Make this manual available to other users of this equipmentCompressor can start any time when plugged Stay ClearUnpacking AssemblyCarton Contents Quick Connect Fitting Connect air tools here Features and ControlsFeatures and Controls Add Oil Break-In ProcedureOperation OperationStarting Your Air Compressor Air Compressor Operating LocationGrounding Instructions Pressure Control KnobStopping Your Air Compressor Extension CordsOverload Protection Reset Compressor OperationSpecifications / Maintenance Product SpecificationsMaintenance Maintenance Service Dates Schedule Service IntervalsInspect Quick Connect Fitting and Tank Drain Valve Inspect Safety ValveMaintenance Inspect / Change Pump OilGeneral Maintenance Cleaning UnitInspect / Clean Air Filter Inspect Safety Labels Inspect Pump Intake and Exhaust ValvesStorage StorageBefore You Call TroubleshootingTroubleshooting Motor will not run Supplying enough air to Operate accessoriesCompressor is not Glossary GlossaryLimited Warranty Règles DE Sécurité Table DES MatièresDescription DE L Équipement Description / Règles DE SécuritéAvertissement Règles DE SécuritéMise EN Garde ÉLOIGNEZ-VOUSContenu de la boîte AssemblageAssemblage DéballageSoupape de relâchement de surpression non illustrée Fonctions ET CommandesFonctions ET Commandes Procédure de rodage OpérationAjoutez de l’huile OpérationDémarrage de votre compresseur d’air Emplacement du compresseur d’air lors de l’utilisationDirectives de mise à la terre ’UTILISEZ PAS UN Adaptateur DE Mise À LA TerreFermez le robinet de vidange Arrêt de votre compresseur d’airRallonges Remarque Évitez d’utiliser des rallongesBouton de Utilisation du compresseurRéarmement du protecteur de surcharge RéarmementSpécifications / Entretien SpécificationsEntretien Fréquence C.A HzVérifiez/changez l’huile de la pompe EntretienVérifiez la soupape de sûreté Vérification du niveau d’huileEntretien général Nettoyage de l’unitéVérifiez/nettoyez le filtre à air Vérifiez les étiquettes de sécurité EntreposageEntretien / Entreposage Remarque Remplacez le filtre s’il est extrêmement saleDépannage DépannageAvant de nous contacter Le moteur ne fonctionne pas Le compresseur ne fournit pasSuffisamment d’air pour le Glossaire GlossaireRemarques RemarquesPériode DE Garantie Reglas DE Seguridad Tabla DE ContenidosDescripción DEL Equipo Descripción Y Reglas DE SeguridadAdvertencia Reglas DE SeguridadPrecaución Manténgase AlejadoContenido de la caja MontajeMontaje DesembalajeAcoplamiento para conector rápido Permiten conectar Características Y MandosCaracterísticas Y Mandos Bomba del compresor de aire La bomba comprime el aire enProcedimiento de preparación para el uso inicial OperaciónAñadir aceite OperaciónPuesta en marcha del compresor de aire Colocación del compresorInstrucciones de conexión a tierra No Utilice UN Adaptador DE Conexión a TierraNota No utilice cables prolongadores Parada del compresor de aireCables prolongadores Rearme de la protección contra sobrecarga Botón ResetUso del compresor Especificaciones / Mantenimiento EspecificacionesMantenimiento Inspeccione / cambie el aceite de la bomba MantenimientoInspeccione la válvula de seguridad Comprobación del nivel de aceiteMantenimiento general Limpieza de la unidadInspeccione / limpie el filtro de aire Nota Sustituya el elemento filtrante si está muy sucio Inspeccione las válvulas de admisión y escape de la bombaInspeccione las etiquetas de seguridad Almacenamiento AlmacenamientoAntes de llamar Diagnositicos DE AveríasDiagnositicos DE Averías Accesorios El compresor no suministra aireSuficiente para accionar los El motor no funcionaGlosario GlosarioNotas NotasPeríodo DE Garantía