PROBLEM | CAUSE | CORRECTION | |
|
|
| |
Pressure reading on | It is normal for "some" | If there is an excessive | |
the regulated pressure | pressure drop to occur. | amount of pressure drop | |
gauge drops when an |
| when the accessory | |
accessory is used. |
| is used, adjust the | |
|
| regulator following | |
|
| the instructions in | |
|
| the Description of | |
|
| Operation paragraph in | |
|
| the Operation Section. | |
|
| NOTE: Adjust the | |
|
| regulated pressure | |
|
| under flow conditions | |
|
| (while accessory | |
|
| is being used). | |
|
|
| |
Compressor is not | Prolonged excessive | Decrease amount | |
supplying enough air to | use of air. | of air usage. | |
operate accessories. |
|
| |
Compressor is not | Check the accessory | ||
| |||
| large enough for | air requirement. If | |
| air requirement. | it is higher than the | |
|
| SCFM or pressure | |
|
| supplied by your air | |
|
| compressor, you need | |
|
| a larger compressor. | |
|
|
| |
| Hole in hose. | Check and replace | |
|
| if required. | |
|
|
| |
| Check valve restricted. | Contact a Trained | |
|
| Service Technician | |
|
|
| |
| Air leaks. | Tighten fittings. | |
|
|
| |
Regulator knob has | Damaged regulator. | Replace. | |
continuous air leak. |
|
| |
|
|
| |
Regulator will not | Damaged regulator. | Replace. | |
shut off air outlet. |
|
| |
|
|
|