OPERATION

KNOW YOUR AIR COMPRESSOR

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

On(I)/Off(O) Switch

Outlet

 

 

Pressure

 

Gauge

Tank

Pressure

Gauge

 

 

Quick

Safety

 

Connect

Valve

 

 

Regulator

 

DESCRIPTION OF OPERATION

Become familiar with these controls before operating the unit.

On(I)/Off(O) Switch: Place this switch in the On (I) position to provide automatic power to the pressure switch and Off (O) to remove power at the end of each use.

Pressure Switch (not shown): The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.

Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Turn regulator knob clockwise to increase pressure and counterclockwise to decrease pressure.

Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

11 - ENG

1000002853

Image 11
Contents C6001 Hazard Safety Guidelines DefinitionsImportant Safety Instructions Risk of Explosion or Fire What can Happen HOW to Prevent ITRisk to Breathing Asphyxiation What can Happen HOW to Prevent ITRisk of Bursting Attachments & accessoriesElectrical Grounding Failure Risk of Electrical Shock What can Happen HOW to Prevent ITRisk from Moving Parts Risk from Flying Objects What can Happen HOW to Prevent ITRisk of HOT Surfaces What can happen Risk of Unsafe Operation What can Happen HOW to Prevent ITRisk of Falling Risk of Injury from LiftingModel No C6001 GlossaryRisk from Noise Duty Cycle AccessoriesAssembly InstallationExtension Cords Voltage and Circuit ProtectionDescription of Operation OperationKnow Your AIR Compressor How to Stop HOW to USE Your UnitCustomer Responsibilities MaintenanceTo Check Safety Valve How to StartTo Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator StorageReplacement Parts ServiceProblem Cause Correction TroubleshootingProblem Cause Correction Problem Cause Correction Incorrect USE can Cause Hazards Follow These Instructions Full ONE Year WarrantyConsignes DE Sécurité Importantes Mesures DE Sécurité DéfinitionsCe qui peut se produire Comment l’Éviter Risque D’EXPLOSION OU D’INCENDIERisque D’ÉCLATEMENT Pneus AccessoiresCE QUI Peut SE Produire Comment L’ÉVITER Consulter les directives relatives La mise à la terre sous « Installation »Risque DE Choc Électrique Mise à la terre électrique le faitPièces Mobiles Risque Associé AUXRisque DE Chute Risque DE Blessure EN Soulevant LE Produit SpecificationsLexique CE QUI Peut SE Produire Comment L’ÉVITERMontage DE Lappareil Cycle DE ServiceAccessoires AssemblageProtection Contre LA Surtension ET Protection DU Circuit RallongesTransport DéplacementDescription du fonctionnement UtilisationFAMILIARISEZ-VOUS Avec Votre Compresseur Dair Arrêt de lappareil Utilisation DE LappareilProtecteur de surcharge du moteur Le moteur Mise en marche EntretienResponsabilités DU Client Avant chaque mise en marcheVidange DU Réservoir Vérification DE LA Soupape DE SûretéEntretien ET Réglages Remplacement OU Nettoyage DE LA Soupape DE RetenuePour Remplacer LE Régulateu RangementPièces DE Rechange \SERVICEEntretien ET Réparation Problème Cause Correction DépannageRemarque Ajustez la Faire vérifier par un technicien Garantie Complète D’UN 1 AN Indica una situ Definiciones DE Normas DE SeguridadInstrucciones Importantes DE Seguridad Indica una SituaciónPeligro ¿QUÉ Puede SUCEDER? Cómo Evitarlo Riesgo DE ExplosiónNeumáticos Elementos y accesoriosRiesgo DE Objetos Despedidos Riesgo POR Piezas Móviles Riesgo DE Caídas Riesgo POR Ruidos Cuadro DE EspecificacionesGlosario Riesgo DE Lesión POR Levantar Mucho PesoInstrucciones Para Conectar a Tierra Ciclo DE ServicioEnsamblaje InstalaciónProtección DEL Voltaje Y DEL Circuito Cables DE Extensión EléctricaNo Utilice UN Adaptador Levantar la unidad TransporteDescripción DE Operaciones OperaciónConozca SU Compresor DE Aire Cómo Utilizar SU Unidad Cómo Verificar LA Válvula DE Seguridad MantenimientoResponsabilidades DEL Cliente Cómo Drenar EL Tanque Servicio Y AjustesPara Reemplazar o Limpiar la Válvula Retención Almacenaje Mantenimiento Y Reparaciones AccesoriosServicio Piezas DE RepuestoAgua. No sobreajuste Guía DE Diagnóstico DE ProblemasProblema Causa CorrecciónNota Ajuste El motor no funciona Fusible Fundido Garantía Completa DE UN AÑO 1000002853 1000002853 Deltaportercable.com