Epson 28-276 instruction manual Extension Cords, Fig. C

Page 6

3.240 VOLT SINGLE PHASE OPERATION

The motor supplied with your machine is a dual voltage, 120/240 volt motor. It is shipped ready- to-run for 120 volt operation. However, it can be converted for 240 volt operation.

A qualified electrician should do the conversion, or the machine can be taken to an Authorized Delta Service Center. When completed, the machine must conform to the National Electric Code and all local codes and ordinances.

The machine is converted by re-wiring the motor for 240 volts, installing a 240 volt plug on the power supply cord and replacing the switch with one that is rated for 240 volt operation.

Be sure the 240 volt plug is only used in an outlet having the same configuration as the plug illustrated in Fig. C. No adapter should be used with the 240 volt plug.

In all cases, make certain that the receptacle in question is properly grounded.

If you are not sure, have a qualified electrician check the receptacle.

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE IS LONGEST OF THE 3 BLADES

Fig. C

EXTENSION CORDS

Use proper extension cords. Make sure your extension cord is in good condition and is a 3- wire extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D-1 or D-2, shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

 

Total Length

gauge of

Rating

Volts

of Cord in Feet

Extension Cord

 

 

 

 

0-6

120

up to 25

18 AWG

0-6

120

25-50

16 AWG

0-6

120

50-100

16 AWG

0-6

120

100-150

14 AWG

 

 

 

 

6-10

120

up to 25

18 AWG

6-10

120

25-50

16 AWG

6-10

120

50-100

14 AWG

6-10

120

100-150

12 AWG

10-12

120

up to 25

16 AWG

10-12

120

25-50

16 AWG

10-12

120

50-100

14 AWG

10-12

120

100-150

12 AWG

 

 

 

 

12-16

120

up to 25

14 AWG

12-16

120

25-50

12 AWG

12-16

120

greater than 50 feet not recommended

 

 

 

 

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

 

Total Length

gauge of

Rating

Volts

of Cord in Feet

Extension Cord

 

 

 

 

0-6

240

up to 50

18 AWG

0-6

240

50-100

16 AWG

0-6

240

100-200

16 AWG

0-6

240

200-300

14 AWG

 

 

 

 

6-10

240

up to 50

18 AWG

6-10

240

50-100

16 AWG

6-10

240

100-200

14 AWG

6-10

240

200-300

12 AWG

10-12

240

up to 50

16 AWG

10-12

240

50-100

16 AWG

10-12

240

100-200

14 AWG

10-12

240

200-300

12 AWG

 

 

 

 

12-16

240

up to 50

14 AWG

12-16

240

50-100

12 AWG

12-16

240

greater than 100 feet not recommended

 

 

 

 

Fig. D-1

Fig. D-2

6 - English

Image 6
Contents Contractors Saw Table of Contents Important Safety InstructionsSafety Guidelines Definitions General SAFETY RULES ADDITIONAL SPECIFIC SAFETY RULES SAVE THESE InstructionsPower Connections MOTOR SPECIFICATIONSGrounding Instructions EXTENSION CORDS Fig. CCarton Contents Functional DescriptionModel 28-206 Enclosed Stand Parts Model 28-276 Open Stand Parts Assembly Time Estimate AssemblyAssembly Tools Required Model 28-206 Enclosed Stand AssemblyPage Model 28-276 Open Stand Assembly Page Attaching the SAW to the Stand Attaching the Belt to the SAW and Motor PulleyAttaching the Pulley Guards Attaching Blade to the SAW CONNECTING MOTOR CORD TO SWITCH ASSEMBLYDisconnect the machine from the power source Table InsertLocking the switch in the off position Starting and stopping the sawTilting the table Adjusting the table stop Adjusting blade tensionVertical Adjustment of the upper Blade guide assembly Adjusting Tightness of ANTI-DROP ScrewTracking the blade Adjusting the upper blade guides and blade support bearing EnglishAdjusting lower blade guides and blade support bearing Dust PortChanging Blade Speed for Model 28-206 only Troubleshooting Guide CUTTING CURVESRemedy Probable Cause Remedy Pointer out of adjustmentProbable Cause Probable Cause RemedyBand SAW Blades Maintenance ServiceAccessories WarrantyService and Repairs LES Instructions Importantes DE Surete Mesures DE Sécurité DéfinitionsRègles DE Sécurité Générales Règles Spécifiques Additionnelles De Sûreté Conserver CES DirectivesInstructions DE Mise À LA Terre Raccordements ÉlectriquesSpécifications DU Moteur FrenchCordon DE Rallonge Fonctionnement Monophasé À 240 VoltsAVANT-PROPOS Description FonctionnelleContenus DE Boite Désemballage ET NettoyagePièces DU Socle Fermé DU Modèle Pièces DU Socle Ouvert DU Modèle Durée Estimée Pour L’ASSEMBLAGE AssemblageOutils Nécessaires Pour L’ASSEMBLAGE Assemblage DU Socle Fermé DU ModèleFrench Assemblage DU Socle Ouvert DU Modèle French Assemblage DE LA Scie SUR LE Socle Assemblage DES Protecteurs DE PoulieAssemblage DE LA Lame SUR LA Scie Connexion DU Cordon Moteur À L’ENSEMBLE DE L’INTERRUPTEURAssemblage DE LA Table SUR LA Scie Insert DE TableVerrouiller L’INTERRUPTEUR EN Position D’ARRÊT FonctionnementDémarrage ET Arrêt DE Scie Inclinaison DE LA TableRéglage DE LA Butée DE LA Table Réglage DE LA Tension DE LameAlignement DE LA Lame Ne jamais aligner la lame lorsque l’appareil fonctionneRéglage DU Serrage DE LA VIS DE Prévention DE Tombée Débrancher l’appareil de la source d’alimentation Goulotte À Poussière Coupe DE CourbesProblème LA Scie À Ruban Vibre Beaucoup Cause probable Problème LA Scie NE Démarre PAS Cause probable SolutionGuide DE Dépannage Problème LES Lames Cassent Cause probableLames DE Scie À Lame Ruban Problème LA Lame NE S’ALIGNE PAS Cause probableEntretien Accessoiries GarantieInstrucciones DE Seguridad Importantes Pautas DE SEGURIDAD/DEFINICIONESNinguna aplicación de otra manera que para que se diseñó Normas Generales DE Seguridad Guarde Estas Instrucciones Normas Específicas Adicionales DE SeguridadConexiones a LA Fuente DE Alimentación ESPECIFICACIONES DEL MOTORCordones DE Extensión Fig. D1Descripción Funcional Contenido DE CartonPrologo Piezas Cerradas DEL Soporte DEL Modelo Base Tornillo de cabeza troncocónica M5 x 0.8 x 10 mm LadoPiezas Abiertas DEL Soporte DEL Modelo Estimación DEL Tiempo DE Ensamblaje EnsamblajeHerramientas DE Ensamblaje Requeridas Montaje DE LA Base DE Soporte Cerrada ModeloNota Apriete libremente el hardware para el ajuste adicional Montaje DE LA Base DE Soporte Abierta Modelo DA BPage Sujeción DE LA Sierra a LA Base DE Soporte Conectar LA Agujeros DEL Protector DE LA PoleaSujeción DE LA Hoja a LA Sierra Cuerda DEL Motor QUE Conecta a LA Asamblea DE InterruptorSujeción DE LA Mesa a LA Sierra Montaje DE LA Pieza DE Insercion DE MesaBloqueando EL Interruptor EN LA Posicion DE Apagado OperaciónArrancando Y Deteniendo LA Sierra Inclinación de la tablaAjuste de la parada de la tabla Ajuste de la tensión de la láminaSeguir la lámina Ajuste Vertical del montaje superior de la guía de la láminaAjuste DE LA Tensión DEL Tornillo CON Bloqueo Reajustar Piezas CON Bloqueo CON Accesorios DE AlturaDesconecte la maquina de la fuente de energia Utilizar LA Maquina Puerto del polvoCausa probable Guia Localizacion DE FallasCorte DE Curvas RemedioRemedios Mantenimiento Hojas DE Sierra DE CintaMantenga LA Máquina Limpia Lubricación Y Protección Contra Óxido ServicioFalla EN EL Encendido Mantenimiento Y ReparacionesAccesorios Identificación DelproductoExcepciones Garantia Para Otras LocalidadesGarantía limitada de dos años para productos nuevos