Conair UGR003/0800 manual Use the Forward arrow, Continue to move through the motion

Page 39

3 Use the Up and Down arrows

to move sequentially through the mold sequence positions. Each mold sequence position under- lines each time the Up or Down arrow is pressed.

4 Use the Forward arrow

to toggle between the choices for that motion sequence position. Each time the arrow is pressed, the cursor moves to the next letter/num- ber and underlines it.

5 Continue to move through the motion

sequence positions using the Up/Down arrows and the Forward arrow until you make all your choices.

6 Press the Enter button.

After making all of your choices for the motion sequence, press the Enter button to program your choice.

PROGRAMMING

THE MOTION

SEQUENCE

CONTD

7

Press the Stop button.

To continue, press the Stop button.

Basic Motion Sequence

10

HOME

 

 

 

 

6

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

9

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

2

48

3

HOME Home position (start, standby position)

1Strip frame slide down and main arm descends (mold open)

2Strip forward

3Grip

4Strip backward.

5Main arm ascends and strip frame slides up.

6Arm traverses outward and wrist flip moves to horizontal position.

7Strip frame slides down and main arm descends.

8Grip releases part.

9Arm ascends and strip frame slides up.

10Arm traverses inward and wrist flip moves to vertical position. Arm returns to Home position.

UGR003/0900

UCR-150L Robot

OPERATION 4-9

Image 39
Contents UCR-150L Robot Date Document Number Introduction Table of ContentsMaintenance Introduction Purpose User Guide HOW the User Guide is OrganizedYour Responsibility AS a User Read this SO no ONE Gets Hurt Page Description What is ROBOT?Typical Applications Robot Works HOWWrist flip cylinder Robot FeaturesFront view Side view SpecificationsOptional Equipment Extended strip strokeEnd-of-arm tooling Installation Remove all packing material Unpacking the BoxesInstallation Preparing for Installation Mounting pattern for the UCR-150L Robot Preparing the PlatenPositioning the Robot Connecting the RobotCheck to see what the power output is from Connect the SPI connector cable intoPlug the hand-held control into the control Set the gripper height to the sprue Setting Gripper PositionTighten the adjustment screws on the block Open the mold Hold the main arm and loosen the arm heightSetting Strip Positions Adjusting Sprue Verification Switch Connecting AIR PressureAdjusting the Speed Verifying motion controls permissives Verifying Electrical InterfaceMold Full Open Verifying the InputsManual Testing Automatic Testing Press the Stop buttonPress the Auto/Recycle button Page Operation Before Starting Hand Control FeaturesStarting the Robot Stopping the RobotEmergency Stopping Grips Viewing InformationOperating Manually Starting Automatic Operation Press the Enter button Choosing the MoldPress the Program button Use the Up and Down arrowsProgramming Motion Sequence Press Stop buttonPress Program button Continue to move through the motion Use the Forward arrowPress the Function button Programming HOME, Grip Vacuum PositionsChoose the function and settings you want Use the right arrow to choose the settingPress the Stop button to continue Inputs Monitoring INPUT/OUTPUTPress the Forward button Setting Timer ValuesEnter the new timer value Press the Time buttonTimer Setting Description LCD Displays Choosing Timer SettingsAdjusting Traverse Movement Use the Motion Control buttons Answering AN AlarmOpen the safety door and verify that there is Restarting Automatic OperationMaintenance Maintenance Features Maintenance Daily Preventative Maintenance ScheduleMonthly Checking Electrical Connections Be sure the main power is disconnectedTroubleshooting Identifying Cause of a Problem Before BeginningFEW Words of Caution Error Display Area of problem Robot Does not Cycle Symptom Possible cause SolutionMold is Not Working Properly Safety interlock is on. Check the output and wiringARM is Not Working Properly Strip Motion Is not Working Horizontal Motion There is noGripper does not work Gripper Does not WorkThere is no vac Air pressure is incor Uum Rect WE’RE Here to Help HOW to Contact Customer Service Before YOUFrom outside the United States, call Appendix GUARANTEE/WARRANTY Electrical Diagrams Solenoid and Limit Switch Wiring Relay and IMM Interface Solenoid Valves Page PARTS/DIAGRAMS PARTS/LISTS Ref. Part No Description Traverse Cylinder IMR004/0800 UCR-150L Robot PARTS/DIAGRAMS P/D-5 Valve IMR004/0800 UCR-150L Robot PARTS/DIAGRAMS P/D-7 Valve Parts JSU6 Slide Base YSA10DC-50B Strip Cylinder U3-MA0-LS Main Arm Description Quantity Main Arm Slide Unit LM20UU Main Cylinder IMR004/0800 UCR-150L Robot PARTS/DIAGRAMS P/D-19 Wrist Flip TANSI6P Wrist Flip Cylinder IMR004/0800 UCR-150L Robot PARTS/DIAGRAMS P/D-23 Gripper Assembly D12 D9191 Assembly, Gripper, with LS-4 Gripper GXL-8F Controller HW-CB116B