Digital Display / Écran numérique / Pantalla digital / Digitale display / Display digitale
Error Codes
Display | Sprayer Operation | Indicates | What To Do |
|
|
|
|
|
|
|
|
No Display | Sprayer stops. Power is not applied. Sprayer | Loss of power. | Check power source. Relieve |
| may be pressurized. |
| pressure before repair or |
|
|
| disassembly. |
|
|
|
|
3000 psi | Sprayer is pressurized. Power is applied. | Normal operation. | Spray. |
210 bar | (Pressure varies with tip size and pressure |
|
|
21 MPa | control setting.) |
|
|
|
|
|
|
E=02 | Sprayer may continue to run. Power is | Pressure greater than | Replace pressure control board |
| applied. | 4500 psi (310 bar, | or pressure transducer. |
|
| 31 mpa) or a pressure |
|
|
| transducer is faulty. |
|
|
|
|
|
E=03 | Sprayer stops. Power is applied. | Pressure transducer | Check transducer connection. |
|
| faulty, bad connection | Open drain valve. Substitute |
|
| or broken wire. | new transducer for transducer |
|
|
| in sprayer. If sprayer runs, |
|
|
| replace transducer. |
|
|
|
|
E=04 | Sprayer stops. Power is applied. | Line voltage too high. | Check for voltage supply |
|
|
| problem. |
|
|
|
|
E=05 | Sprayer does not start or stops. Power is | Motor fault. | Check for locked rotor, shorted |
| applied. |
| wiring or disconnected motor. |
|
|
| Repair or replace failed parts. |
|
|
|
|
- - - - | Power is applied. | Pressure is less than | Increase pressure if desired. |
|
| 200 psi (14 bar, 1.4 MPa). | Drain valve may be open. |
|
|
|
|
EMPTY | Sprayer stops. Power is applied. | Empty paint pail. Loss of | Refill paint pail. Check for leaks |
|
| pressure. | or clogged pump inlet. Repeat |
|
|
| Startup procedure. |
|
|
|
|
44 | 311905B |