QUICK CLEAN MODE
LOW operation
POLLEN mode operation MAX operation MEDIUM operation

QUICK CLEAN MODE

QUICK CLEAN Mode with humidification releases high-density Plasmacluster ions. By con- tinuously discharging strong airflow cycles, the unit effectively removes airborne dust, pollen, mold and allergens from the air as they are drawn through the filter system. Water must be in the Water Tank when this mode is selected.

The unit humidifies when there’s water in the Water Tank, and it operates without humidifying when there is no water in it.

1 Press the QUICK CLEAN MODE Button on the display to select this mode.

When the operation finishes, the unit will return to the prior operation.

FAN SPEED Button

Press the FAN SPEED Button to select the preferred fan settings. Indicator lights will show the speed currently selected. Please note the fan speed cannot be adjusted during the QUICK CLEAN Mode.

AUTO operation

The fan speed is automatically switched (HIGH*, MEDIUM, LOW) depending on the amount of impurities in the air. The sensors detect the impurities for efficient air purification.

The unit will operate at High level for 0 minutes, then will FAN SPEED ButtonPlasmacluster ON/OFF ButtonPOWER OFF ButtonE-3Manual backgroundManual backgroundManual background alternated between MED and HIGH every 20 minutes.

The unit will operate at maximun fan speed .

The unit will operate at medium fan speed .

Manual backgroundManual backgroundManual backgroundManual background The unit will operate quietly using minimal air intake. * HIGH fan speed is an intermediate speed between MEDIUM and MAX.

Plasmacluster ON/OFF Button

Press the Plasmacluster ON/OFF Button to turn Plasmaclus- ter Ion Mode ON and OFF. When Plasmacluster is ON, both the Indicator Light and Plasmacluster Indicator Light on the front display turn on.

POWER OFF Button

Press the Power OFF Button to turn the unit off.

ENGLISH

E-3

Image 15
Contents MANUAL DE OPERACIÓN AIR PURIFIER with Humidifying FunctionPurificateur d’air à fonction d’humidification MANUEL D’UTILISATION PURIFICADOR DE AIREWashable Deodorizing filter black Pre-filter True HEPA filter whiteFEATURES CONTENTSENGLISH Sharp Electronics Corporation ACCESSORIES ADDITIONAL CUSTOMER INFORMATIONFOR CUSTOMER ASSISTANCE the United States PARTS for your Authorized Parts DistributorWarranty Period for this Product CONSUMER LIMITED WARRANTYSHARP ELECTRONICS CORPORATION CONSUMER LIMITED WARRANTY FOR U.S. USERSACCESSORIES ADDITIONAL CUSTOMER INFORMATION FOR CUSTOMER ASSISTANCE Canada335 Britannia Road East Mississauga, Ontario L4Z 1W9SERVICE LIMITED WARRANTYConsumer Electronics Products Congratulations on your purchaseIMPORTANT SAFETY INSTRUCTIONS ENGLISH INSTALLATION GUIDELINESCAUTIONS CONCERNING OPERATION FILTER GUIDELINESILLUSTRATIVE DIAGRAM - FRONT PART NAMESBACK Indicator Light red MAIN UNIT DISPLAYFRONT MONITOR Filter Reset Button 1 Remove the filters FILTER INSTALLATION 2 Install the filters Install the True HEPA filter4Replace the Water Tank in the unit REFILLING THE WATER TANK1 Removetop. the Water Tank by unlatching the 3After filling, securely tighten the Tank Cap1 Press the CLEAN AIR MODE Button on the display CLEAN AIR & HUMIDIFY MODECLEAN AIR MODE 2 PressButton.the CLEAN AIR & HUMIDIFY MODEPlasmacluster ON/OFF Button QUICK CLEAN MODEPOWER OFF Button FAN SPEED Button3 Press the Power OFF Button WATER SUPPLY INDICATOR LIGHTADJUSTMENT OF SENSOR DETECTION SENSITIVITY Sound indicator setting for water supplyBACK PANEL and SENSORS CARE AND MAINTENANCEFILTER INDICATOR LIGHT Care Cycle When the back panel has stubborn dirt4 Replace the filter in unit. See E-10 WATER TANKWASHABLE DEODORIZING FILTER CARE 2Drip dry filter to remove excess water2Rinse the Humidifying Tray with lukewarm water HUMIDIFYING TRAYCARE AND MAINTENANCE HUMIDIFYING FILTER1Remove the Water Tank and Humidifying Tray 3 Preparingtion. the descaling soluReplacing the Filters FILTER REPLACEMENT GUIDELINESGuide for filter replacement timing Replacement FiltersE-20 TROUBLESHOOTINGHumidify Indicator Light ERROR DISPLAYE-2 Flashing of the Clean AirSPECIFICATIONS E-22Standby Power ENGLISH Filtre désodorisant lavable noir Pré-filtre Filtre HEPA authentique blancFRANÇAIS CARACTÉRISTIQUESTABLE DES MATIÈRES POUR VOUS PROTÉGER LE SERVICE GARANTIE LIMITÉEProduits Électronique grand public Bravo! Vous Venez de faire un excellent achatINSTRUCTIONS DE SÉCURITÉ IMPORTANTES FRANÇAIS GUIDE D’INSTALLATIONPRÉCAUTIONS CONCERNANT LE FONCTIONNEMENT GUIDE D’UTILISATION DES FILTRESDÉSIGNATION DES PIÈCES SCHÉMA ILLUSTRATIF - AVANTDOS DE L’APPAREIL des témoins AFFICHAGE DE L’UNITÉ PRINCIPALEMONITEUR AVANT FRANÇAIS1 Retirez les filtres INSTALLATION DES FILTRES2 Installez les filtres 1 Installez le filtre HEPA authentique4 Replacez le réservoir d’eau dans l’appareil REMPLISSAGE DU RÉSERVOIR D’EAUAprès le remplissage, serrez bien le bou 3 chon du réservoirFONCTIONNEMENT MODE D’ÉPURATION DE L’AIRMODE D’ÉPURATION DE L’AIR ET D’HUMIDIFICATION Bouton DE MARCHE/ARRÊT DU Plasmacluster MODE D’ÉPURATION RAPIDEBouton DE VITESSE DU VENTILATEUR Bouton D’ARRÊT DE L’APPAREILAnnulation Bouton DE CONTRÔLE DES TÉMOINSLAMPE D’ALIMENTATION EN EAU RÉGLAGE DE LA SENSIBILITÉ DES CAPTEURSAPPAREIL SOIN ET ENTRETIENLAMPE DU FILTRE PANNEAU ARRIÈRE ET CAPTEURSRÉSERVOIR D’EAU SOIN ET ENTRETIENENTRETIEN DU FILTRE DÉSODORISANT LAVABLE F-5 BAC D’HUMIDIFICATIONFILTRE D’HUMIDIFICATION F-6SOIN ET ENTRETIEN Filtres de rechange GUIDE DE REMPLACEMENT DES FILTRESGuide de remplacement des filtres Remplacement des filtresF-8 RÉSOLUTION DES PROBLÈMESClignotement de la lampe AFFICHAGE D’ERREURF-9 FRANÇAISCARACTÉRISTIQUES F-20Consommation en veille FRANÇAIS F-2NOTA Lea antes de operar su nuevo Purificador de aireESPAÑOL CARACTERÍSTICASCONTENIDO INSTRUCCIONES DE SEGURIDAD IMPORTANTES ESPAÑOL PRECAUCIONES RELACIONADAS CON LA OPERACIÓNPAUTAS PARA LA INSTALACIÓN PAUTAS PARA EL FILTRODIAGRAMA ILUSTRATIVO - PARTE FRONTAL NOMBRE DE LAS PARTESPARTE POSTERIOR Botón reestablecer filtro PANTALLA DE LA UNIDAD PRINCIPALMONITOR FRONTAL ESPAÑOL1 Instale el filtro HEPA INSTALACIÓN DEL FILTRO1 Retire los filtros 2 Instale los filtrosLLENADO DEL TANQUE DE AGUA 4 Reemplace el tanque de agua en la unidadPRECAUCIÓN 1 Llene el tanque de agua. Vea S-7 MODO CLEAN AIR AIRE LIMPIO2 Presione el botón de Modo CLEAN AIR OPERACIÓNBotón Plasmacluster ON/OFF ENCENDIDO/APAGADO MODO QUICK CLEAN LIMPIEZA RÁPIDABotón POWER OFF APAGADO Botón FAN SPEED VELOCIDAD DEL VENTILADOROPERACIÓN Botón LIGHTS CONTROL CONTROL DE LUCESLUZ DEL INDICADOR DE SUMINISTRO DE AGUA AJUSTE DE LA SENSIBILIDAD DE DETECCIÓN DEL SENSORUNIDAD CUIDADO Y MANTENIMIENTODEL FILTRO PANEL POSTERIOR y SENSORESS-12 TANQUE DE AGUACUIDADO DEL FILTRO DESODORIZADOR LAVABLE 4 Reemplazo del filtro en la unidad. Vea S-6PRECAUCIÓN BANDEJA DEL HUMIDIFICADORFILTRO DEL HUMIDIFICADOR S-14CUIDADO Y MANTENIMIENTO Reemplazo de los filtros PAUTAS PARA REEMPLAZAR EL FILTROGuía para programar el reemplazo del filtro Filtros de reemplazoS-16 LOCALIZACIÓN DE FALLASDestello de la luz del MENSAJES DE ERRORS-17 ESPAÑOLESPECIFICACIONES S-18Energía de reserva ESPAÑOL Sharp Plaza, Mahwah SHARP ELECTRONICS CORPORATIONSHARP CORPORATION SHARP CORPORATION