TABLE 3

Capacity of Type B Double−Wall Vents with Type B Double−Wall Connectors

Serving a Single Category I Appliance

 

 

 

 

 

Vent and Connector Diameter − D (inches)

 

 

 

Height

Lateral

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Inch

 

4 Inch

 

5 Inch

 

6 Inch

H

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appliance Input Rating in Thousands of Btu Per Hour

 

 

 

(feet)

(feet)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MIN

 

MAX

MIN

 

MAX

MIN

 

MAX

MIN

 

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

 

78

0

 

152

0

 

251

0

 

375

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

13

 

51

18

 

97

27

 

157

32

 

232

6

 

 

 

 

 

 

 

 

 

 

 

 

 

4

21

 

49

30

 

94

39

 

153

50

 

227

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

25

 

46

36

 

91

47

 

149

59

 

223

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

 

84

0

 

165

0

 

276

0

 

415

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

12

 

57

16

 

109

25

 

178

28

 

263

8

 

 

 

 

 

 

 

 

 

 

 

 

 

5

23

 

53

32

 

103

42

 

171

53

 

255

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

28

 

49

39

 

98

51

 

164

64

 

247

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

 

88

0

 

175

0

 

295

0

 

447

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

12

 

61

17

 

118

23

 

194

26

 

289

10

 

 

 

 

 

 

 

 

 

 

 

 

 

5

23

 

57

32

 

113

41

 

187

52

 

280

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

30

 

51

41

 

104

54

 

176

67

 

267

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

 

94

0

 

191

0

 

327

0

 

502

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

11

 

69

15

 

136

20

 

226

22

 

339

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

5

22

 

65

30

 

130

39

 

219

49

 

330

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

29

 

59

40

 

121

51

 

206

64

 

315

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

35

 

53

48

 

112

61

 

195

76

 

301

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

 

97

0

 

202

0

 

349

0

 

540

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

10

 

75

14

 

149

18

 

250

20

 

377

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

21

 

71

29

 

143

38

 

242

47

 

367

20

 

 

 

 

 

 

 

 

 

 

 

 

 

10

28

 

64

38

 

133

50

 

229

62

 

351

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

34

 

58

46

 

124

59

 

217

73

 

337

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

48

 

52

55

 

116

69

 

206

84

 

322

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

 

100

0

 

213

0

 

374

0

 

587

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

9

 

81

13

 

166

14

 

283

18

 

432

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

21

 

77

28

 

160

36

 

275

45

 

421

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

10

27

 

70

37

 

150

48

 

262

59

 

405

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

33

 

64

44

 

141

57

 

249

70

 

389

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

56

 

58

53

 

132

66

 

237

80

 

374

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

NR

 

NR

73

 

113

88

 

214

104

 

346

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE − Single appliance venting configurations with zero lateral lengths are assumed to have no elbows in the vent system. For all other vent configurations, the vent system is assumed to have two 90° elbows. For each additional 90° elbow or equivalent (for example two 45° elbows equal one 90° elbow) beyond two, the maximum capacity listed in the venting table should be reduced by 10 percent (0.90 x maxi- mum listed capacity).

Page 18

Image 18
Contents Installation Instructions SL280UHV Table of ContentsSide Return Air Opening Unit Dimensions − inches mmReturn air from both sides Either SideAccess Panel Blower Assembly Parts ArrangementSight Glass Safety Information SL280UHV Gas FurnaceShipping and Packing List Air Handler Unit Use of Furnace as Construction HeaterGeneral EvaporatorCombustion, Dilution & Ventilation Air Equipment in Confined Space ALL AIR from InsideEquipment in Confined Space ALL AIR from Outside Equipment in Confined SpaceEquipment Confined Space ALL AIR from Outside Setting Equipment BottomBlower Motor Rigid LEG Indoor AIR 20 X 25 XFurnace Front Return AIR BaseEnd Bottom Horizontal Application Installation Clearances Top LeftRight Typical Horizontal ApplicationFilters Duct SystemTop Vent Discharge VentingUpflow Position Left Side Vent DischargeHorizontal Left Position Horizontal Right PositionSide Vent Discharge Sticker Common Venting Using Metal−Lined Masonry ChimneyDisconnected Vent Vent PipeVent Connector Through an unused masonry chimney flue is not considered102 127 −1/2 152 178 10−1/2 MIN MAX Feet FAN + FAN FAN + NAT 130 Carbon Monoxide Poisoning Hazard Gas Piping Ers or straps. Install a drip leg in vertical pipe runs to− In some localities, codes may require the installation Every 8 to 10 feet 2.44 to 3.01 m with suitable hangHorizontal Application Left−Side Air DischargeRight−Side Air Discharge Electrostatic Discharge ESD Interior MAKE−UP BOX InstallationElectrical BOXNon−Communicating CommunicatingIcomfortt Integrated Control Outdoor Unit Icomfort Touch 120V Connections NON−COMMUNICATING System WiringCommunicating System Wiring ApplicationsDIP Switch Settings and On−Board Links See figure OFF Single Stage Thermostat w Dual fuel capa Bilities SL280UHV Schematic Wiring Diagram Typical SL280UHV Field Wiring Diagram Integrated Control RS−BUS Link TB82, future use+ = Data High Connection − = Data LOW Connection −10% approx OFF On−Board Links 940 1045985 880SL280UH090V36B Blower Performance less filter 1155 12801220 10951170 12951235 11101165 13601230 11001160 12901225 1380+18% 1605 SL280UH110V60C Blower Performance less filter +18% 1785 SL280UH135V60D Blower Performance less filter Operating Sequence Compressor Thermostat energizes Y2White Rodgers GAS Valve For Your Safety Read Before LightingUnit Start−Up Honeywell GAS ValveProper Combustion Gas Pressure AdjustmentGAS Meter Clocking Chart DialHigh Altitude Other Unit Adjustments Heating Sequence of OperationHeating Operation with TWO−STAGE Thermostat Heating Operation with Single Stage ThermostatSEC Service Electrical SHOCK, Fire Or Explosion Hazard11− Back wash using steam. Begin from the burner opening SL280UHV BURNER, Combustion AIR Inducer Assembly13− To clean the combustion air inducer visually inspect 17− Reinstall burner box, manifold assembly and burner boxSL280UHV NOX Inserts Planned Service Repair Parts ListIntegrated Control Diagnostic Modes Integrated Control Diagnostic CodesPower at the thermostat. Alert stops all services Normal operation 5 seconds after fault recoveredFurnace / air handler. Clears after fault recovered Equipment is unable to communicate. IndicatesControl will still operate on default parameter set Reconfigure the system. Replace control if heatingMissioning and Execute ’Set Factory Default mode’ Ate feature will be set as ’installed’ and that couldFault is cleared Low pressure switch failed openSumes normal operation after fault is cleared Tion after fault is clearedSoft lockout or reset Open or not within specifications −hour soft lockOut. Clears when flame has been proven stable To flame failureError after current is sensed in both RUN Pair/add duct. Cleared after the current service deIs not running. Check power to outdoor unit. Clears Vice is removed, or after power resetSor run cycle, or after power reset Program Unit Capacity/Size Mode FinishedTroubleshooting Heating Sequence of Operation Call for FIRST−STAGE HeatCall for SECOND−STAGE Heat Call for Heat SatisfiedCall for Heat Satisfied FIRST−STAGE Heat SECOND−STAGE Heat 2ND Stage HeatTroubleshooting Cooling Sequence of Operation Call for CoolingTroubleshooting Continuous Fan Sequence of Operation Call for FAN