Introduction

Use this manual to install, startup, operate, and maintain the Custom Climate Changer™ air handler.

Carefully review the procedures discussed in this manual to minimize installation and startup difficulties.

Unit Description

Custom Climate Changer™ air handlers are designed for a variety of controlled-air applications. The basic unit consists of a fan, heating and/or cooling coils, filters, and dampers. See the unit submittal drawings for detailed descriptions.

Each unit is provided with a nameplate. This nameplate includes unit model number, serial number and electrical data.

The fans are internally isolated. To insure fan stability, the unit ships with a minimum of four lock-down devices that prevent the fan from shifting during shipment and installation. These spacers must be removed prior to fan operation to assure proper vibration isolation. Retain these spacers for use in adjusting fan isolators if required.

The units are available with factory mounted controls for climate and humidity control. These can be use as stand-alone devices or operate with a complete controls system. End devices include factory-mounted starters and variable speed drives.

Custom Climate Changer™ air handlers ship as complete assemblies or in sections. Some jobsite assembly is required when the units ship in sections.

Protecting the

Environment

World environmental scientists have concluded, based on the best currently available evidence, that ozone in our upper atmosphere is being reduced due to the release of CFC (chlorofluorocarbon) fully halogenated compounds.

Trane urges that all HVAC servicers working on Trane equipment, or any manufacturer’s products, make every effort to eliminate, if possible, or vigorously reduce the emission of CFC, HCFC (halocarbon that contains fluorine, chlorine, carbon, and hydrogen), and HFC (halocarbon that contains only fluorine, carbon, and hydrogen) refrigerants to the atmosphere resulting from installation, operation, routine maintenance, or major service on this equipment. Always act in a responsible manner to conserve refrigerants for continued use even when acceptable alternatives are available.

Refrigerant used in any type of air- conditioning or refrigerating equipment should be recovered for reuse, recovered and/or recycled for reuse, reprocessed (reclaimed), or properly destroyed, whenever it is removed from equipment. Never release it to the atmosphere!

CAH-SVX01A-EN

3

Image 3
Contents July Custom Climate Changer Air HandlersCAH-SVX01A-EN Protecting Environment Unit DescriptionContents Factory-Mounted Controls Wiring Sizes ConnectionsOperating Environment ControlsUltraviolet UV Germicidal Irradiation Lights optional Use Canvas Only Receiving ChecklistResolving Shipping Damage Job Site Storage RecommendationsOutdoor Storage Considerations Pre-Installation Requirements General StoragePreparing the Unit Site Long-Term StorageTypical Curb Installation Checklist Roof Curb InstallationGeneral Lifting Considerations Lifting and RiggingAssembly Hardware Unit AssemblyJoining Sections Edge-to- Edge TCP Model Assembly InstructionsTCP base assembly TCP Base Section Assembly TypicalTCP Outdoor Roof Section Assembly Typical Installation TCP Wall Section Assembly TypicalInstallation TCP Indoor Roof Section Assembly Typical Indoor Roof Assembly CompleteBase to Wall Assembly Complete Joining sections Edge to Edge TCC Model Assembly InstructionsApply butyl tape to shipping splits Add caulk along the seam Join internal shipping split frame Installation TCC indoor roof sections assembly typical TCC wall sections assembly typicalJoin outdoor roof panels at the seams Installation TCC outdoor roof sections assembly typicalTrim roof joint strip Fans Component Installation RequirementsIsolator Adjustment Duct ConnectionsTraq Dampers Control DampersMagnahelic Air Filter Gage Front Load Filters Installation Air FiltersBag or Cartridge Filters Outdoor Unit Weather HoodsPrevent Coil Damage Use a Backup WrenchCoil Piping Connections General RecommendationsWater Damage Installation Drain Pan TrappingCoil Damage Installation Steam Coil PipingInstallation Typical piping for type 5W one-row water coil Water Coil PipingLiquid Lines Installation Refrigerant Coil PipingType F refrigerant coil with packed elbow Valve DamageSingle-circuit evaporator coil with one distributor Examples of Field-Installed Evaporator PipingSingle-circuit evaporator coil with two distributors Single-circuit evaporator coil with four distributors Dual-circuit evaporator coil with two distributors Dual-circuit evaporator coil with four distributors Dual-circuit evaporator coil with eight distributors Capacitors WiringHazardous Voltage with Use Copper Conductors OnlyExternal Insulating Requirements Junction box mounting and wiring detailsMotor-Related Checks Pre-Startup ChecklistFan-Related Checks Coil-Related Checks Proper Water TreatmentUnit Operation General ChecksCalculate Motor Voltage Imbalance Tension Belts Correctly Startup Tension the Fan BeltStartup Determine Fan Speed Sheave AlignmentMultibelt Check Routine Maintenance Front Load Filters Air FiltersThrowaway Filters Permanent FiltersBearing Set Screw Alignment Inspecting and Cleaning FansDrain Pans FansFan Motor Inspection Fan Bearing LubricationRefrigerant Coils CoilsSteam and Water Coils Type K Cooling CoilsMoisture Purge Cycle Internal Insulation Ultraviolet UV Germicidal Irradiation Lights Replacement of ultraviolet bulbsTroubleshooting Alignment section on CAH-SVX01A-EN CAH-SVX01A-EN Trane