Join outdoor roof panels together at the seams in the direction perpendicular to airflow and secure them in place with 5/16-inch x 3/4-inch bolts and 5/16 lock nuts. Install the roof joint strip to cover the seam between two outdoor roof panels in the perpendicular to airflow direction of. Use 3/8-inch butyl tape to cover the seam between

two outdoor roof panels overhang at the side the unit. Bend joint strip over roof panel and use two number 10 sheet metal screws (one in each roof panel) to secure joint strip. Trim the roof joint strip to insure that it does not protrude more than 1/16-inch beyond outdoor roof overhang (see Figure 18).

Figure 18. Trim roof joint strip

CAH-SVX01A-EN

23

Image 23
Contents July Custom Climate Changer Air HandlersCAH-SVX01A-EN Protecting Environment Unit DescriptionContents Factory-Mounted Controls Wiring Sizes ConnectionsOperating Environment ControlsUltraviolet UV Germicidal Irradiation Lights optional Use Canvas Only Receiving ChecklistResolving Shipping Damage Job Site Storage RecommendationsOutdoor Storage Considerations Pre-Installation Requirements General StoragePreparing the Unit Site Long-Term StorageTypical Curb Installation Checklist Roof Curb InstallationGeneral Lifting Considerations Lifting and RiggingAssembly Hardware Unit AssemblyJoining Sections Edge-to- Edge TCP Model Assembly InstructionsTCP base assembly TCP Base Section Assembly TypicalTCP Outdoor Roof Section Assembly Typical Installation TCP Wall Section Assembly TypicalInstallation TCP Indoor Roof Section Assembly Typical Indoor Roof Assembly CompleteBase to Wall Assembly Complete Joining sections Edge to Edge TCC Model Assembly InstructionsApply butyl tape to shipping splits Add caulk along the seam Join internal shipping split frame Installation TCC indoor roof sections assembly typical TCC wall sections assembly typicalJoin outdoor roof panels at the seams Installation TCC outdoor roof sections assembly typicalTrim roof joint strip Fans Component Installation RequirementsIsolator Adjustment Duct ConnectionsMagnahelic Air Filter Gage Traq DampersControl Dampers Front Load Filters Installation Air FiltersBag or Cartridge Filters Outdoor Unit Weather HoodsPrevent Coil Damage Use a Backup WrenchCoil Piping Connections General RecommendationsWater Damage Installation Drain Pan TrappingCoil Damage Installation Steam Coil PipingInstallation Typical piping for type 5W one-row water coil Water Coil PipingLiquid Lines Installation Refrigerant Coil PipingType F refrigerant coil with packed elbow Valve DamageSingle-circuit evaporator coil with one distributor Examples of Field-Installed Evaporator PipingSingle-circuit evaporator coil with two distributors Single-circuit evaporator coil with four distributors Dual-circuit evaporator coil with two distributors Dual-circuit evaporator coil with four distributors Dual-circuit evaporator coil with eight distributors Capacitors WiringHazardous Voltage with Use Copper Conductors OnlyExternal Insulating Requirements Junction box mounting and wiring detailsMotor-Related Checks Pre-Startup ChecklistFan-Related Checks Coil-Related Checks Proper Water TreatmentCalculate Motor Voltage Imbalance Unit OperationGeneral Checks Tension Belts Correctly Startup Tension the Fan BeltStartup Multibelt Check Determine Fan SpeedSheave Alignment Routine Maintenance Front Load Filters Air FiltersThrowaway Filters Permanent FiltersBearing Set Screw Alignment Inspecting and Cleaning FansDrain Pans FansFan Motor Inspection Fan Bearing LubricationRefrigerant Coils CoilsSteam and Water Coils Type K Cooling CoilsMoisture Purge Cycle Internal Insulation Ultraviolet UV Germicidal Irradiation Lights Replacement of ultraviolet bulbsTroubleshooting Alignment section on CAH-SVX01A-EN CAH-SVX01A-EN Trane