Craftsman 139.5391 owner manual HOW and When to Adjust the Forces, Test the Down close force

Page 28

ADJUSTMENT STEP 2

Adjust the Force

Force adjustment controls are located on the back panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door.

If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction. Weather conditions can affect the door movement, so occasional adjustment may be needed.

The maximum force adjustment range is about 3/4 of a complete turn. Do not force controls

beyond that point. Turn force adjustment controls with a screwdriver.

NOTE: If anything interferes with the door's upward travel, it will stop. If anything interferes with the door's downward travel (including binding or unbalanced doors), it will reverse.

HOW AND WHEN TO ADJUST THE FORCES

1.Test the DOWN (close) force

Grasp the door bottom when the door is about halfway through DOWN (close) travel. The door should reverse. Reversal halfway through down travel does not guarantee reversal on a 1-1/2"

(3.8 cm) obstruction. See Adjustment Step 3, page 29. If the door is hard to hold or doesn't reverse, DECREASE the DOWN (close) force by turning the control counterclockwise. Make small adjustments until the door reverses normally. After each adjustment, run the opener through a complete cycle.

If the door reverses during the down (close) cycle and the opener lights aren't flashing, INCREASE DOWN (close) force by turning the control clockwise. Make small adjustments until the door completes a close cycle. After each adjustment, run the opener through a complete travel cycle. Do not increase the force beyond the minimum amount required to close the door.

2.Test the UP (open) force

Grasp the door bottom when the door is about halfway through UP (open) travel. The door should stop. If the door is hard to hold or doesn't stop, DECREASE UP (open) force by turning the control counterclockwise. Make small adjustments until the door stops easily and opens fully. After each adjustment, run the opener through a complete travel cycle.

If the door doesn't open at least 5 feet (1.5 m), INCREASE UP (open) force by turning the control clockwise. Make small adjustments until door opens completely. Readjust the UP limit if necessary. After each adjustment, run the opener through a complete travel cycle.

Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLYINJUREDor KILLEDby a closing garage door.

Too much force on garagedoor will interfere with proper operation of safety reversalsystem.

NEVERincreaseforce beyond minimum amount required to close garagedoor.

NEVERuse force adjustments to compensatefor a binding or sticking garage door.

If one control (force or travel limits) is adjusted, the other control may also needadjustment.

After ANY adjustments are made,the safety reversal system MUST be tested. Door MUST reverseon contact with 1-1/2" high (3.8 cm) object (or 2x4 laid flat) on floor.

Force Adjustment

Controls

Back panel

\

\l

ADJUSTMENT LABEL

Open Force

Close Force

28

Image 28
Contents Garage Door Opener Abridor DE Puerta DE Cochera Table of Contents Tools needed Preparing your garage doorSectional Door One-Piece Door Sectional Door Installations Sectional Door InstallationPlanning ONE-PIECE Door Without Track ONE-PIECE Door InstallationsONE-PIECE Door with Track Carton Inventory Assembly Hardware Hardware InventoryAssembly Step Assemble the Rail & Install the lolleyInstall the Idler Pulley Fasten the Rail to the Motor UnitInstall the Chain/Cable RexScrewsTighten the Chain InstallationTrolley Installation Step Determine the Header Bracket LocationWall Header Bracket Installation Install the Header BracketCeiling Header Bracket Installation Attach the Rail to the Header Bracket Position the Opener Sectional Door or ONE-PIECEDOOR with TrackHang the Opener HiddenInstall the Door Control Outside Keylock Accessory ConnectionsInstall the Light Attach the Emergency Release Rope and HandleElectrical Requirements Important Information about Safety Reversing Sensor Install The Protector SystemFacing the door from inside the garage Installing the Brackets Wall installationAligning the Safety Sensors Mounting and Wiring the Safety SensorsTroubleshooting the Safety Sensors Sectional Doors Fasten the Door BracketUre ONE-PIECE Doors Screws not provided to fasten the bracket to the doorConnect Door Arm to Trolley Sectional Doors onlyClosed door adjustment decrease Down travel limit Adjustment procedures, FigureALL ONE-PIECE Doors Adjustment Step Adjust the UP and Down Travel LimitsTravel cycle after each adjustment HOW and When to Adjust the LimitsHOW and When to Adjust the Forces Adjust the ForceTest the Down close force Test the Safety Reversal System AdjustTest The Protector System TestOperation Using Your Garage Door OpenerActivate your opener with any of the following Using Wall.Mounted To Open the Door Manually Control Disconnect the TrolleyLockout position TrolleCare of Your Opener Once a MonthTwice a Year Once a YearHaving a PROBLEM? My lights will not turn off when door is openMy remotes will not activate the door My door reverses for no apparent reasonNot glow steady Symptom LED is not lit on door controlTom Motor unit doesnt operate To Add or Reprogram a Hand.held Remote Control Using the Learn Button Using the Premium Control ConsoleProgramming To Erase All Codes From Motor Unit MemoryUsing the Learn Button Using the Premium Control Console Add, Reprogram Or Change Keyless Entry PINRail Assembly Parts Installation Parts Repair PartsDescription MotorUnitAsmblyPas Accessories WA R RJExtemsiOn Bracketsi 139.53786 139i53709DO Gleaan BrakeRevisi6n de los Simbolos y Trminos de Seguridad Preparaci6n de !,,1 puerta de su cochera Herramientas necesariasPlanificaci6n Instalacin CON UNA Puerta SeccionalPlanificaci6n continUa INSTALACI6N CON Puertas DE UNA Sola PiezaInventario de la Caja de Cart6n Inventario de Piezas Rcrascadtrol TORNILLERfA Y Piezas Para LA InstalacinMonte el Riel e instale el Trole Fije el Riel a la Unidad del Motor Instale la Polea LocaIii!iii!iii!iii!iii!iii!iii!iii!iii!iii!iii!iii!iiTEIA Instale la Cadena y CableInstruccion ES IM Portantes Para Apriete la CadenaINSTALACION, Paso Determine d6nde va a instalar La M6nsula del CabezalInstale la Mnsula del Cabezal Coloque el Riel en la Mnsula del Cabezal Coloque el Abridor en Posici6n Retire la espuma de embalajeCuelgue el Abridor Instale la Unidad de Control de la Puerta Conexiones pare la Unidad de Control ExteriorColoque la Cuerda y la Manija de Emergencia Instale la Luce¢!A Requisitos para la Instalaci6n ElctricaSi se instalay se alinea oorreotamente, el sensordel Instale La Sistema de Protecci6nEstos sensoresse deben instalaren el interiorde la Siguientes Instatacl6n en la pazd Flgura 2 yInstatacl6n en el p!$o Flgura La ilustraci6nCOMe Alinear LOS Sensores DE Seguridad INSTALACION, Paso 1 Fije la Mnsula de la PuertaPuertas DE UNA Sola Pieza Conecte el Brazo de la Puerta al Trole FlguraProcedlmlento de ajuste, Flgura Conecte e! braze de la puerta a! troteAjuste el Limite del Recorrido Hacia Arriba y Hacia Abajo St la puerta no se abre per !o menos 1.5 m 5 piesAjuste la Fuerza Pruebe la fuerza de/recorrldo Hacia Arriba abrlrPruebe La Sistema de Protecci6n Pruebe el Sistema de Retroceso de SeguridadAjuste Para reducir el riesgo de lesiones graves o la muerte C6mo Usar su Abridor de Puerta de CocheraC6mo Abrir la Puerta Manualmente C6mo Usar la Unidad de Control de ParedMarius ERTErt¢i AscondicionesSl Tiene Algun Problema Tabla de Diagn6stico Sfntoma E! LED del control de ta puerta no se enclendeC6mo Agrogar o Reprogramar Un Control Remoto Manual Coro Usar LA Consola DE Control PremiumSuelte los botones cuandolab lucos Controles Remotos FuncionesEnoendida por 30 segundos Para porter un PiN temporal$61o estan dlsponlbles a travd$ de Reface!ones y Servlclo SearsMY-HOME