OPERATION

IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of severe injury or death:

1.READAND FOLLOWALL WARNINGSAND INSTRUCTIONS.

2.ALWAYSkeep remote controls out of reach of children. NEVERpermit children to operate or play with garage door control push buttons or remote controls.

3.ONLYactivategarage door when it can be seen clearly, it is properly adjusted, and there are no obstructions to door travel.

4.ALWAYSkeep garagedoor in sight until completely closed. NO ONESHOULDCROSSTHEPATHOFTHE

MOVINGDOOR.

5.NO ONESHOULDGOUNDERA STOPPED,PARTIALLY OPENEDDOOR.

6.If possible, use emergency release handleto disengage trolley ONLYwhen garagedoor is CLOSED.Weakor

broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.

7.NEVERuse emergency releasehandle unless garage doorway is clear of personsand obstructions.

8.NEVERuse handleto pull garagedoor open or closed. If rope knot becomes untied, you could fall.

9.If one control (force or travel limits) is adjusted, the other control mayalso needadjustment.

10.After ANY adjustments are made,the safety reversal system MUST betested.

11.Safety reversalsystem MUST be tested every month. Garagedoor must reverseon contact with 1-1/2" high (3.8 cm) object (or a 2x4 laid flat) on the floor.

12.ALWAYSKEEPGARAGEDOORPROPERLYBALANCED

(see page3). An improperly balanceddoor may not reversewhen required and could result in SEVERE INJURYor DEATH.

13.All repairs to cables, spring assemblies and other hardware,all of which are under EXTREMEtension,

MUST be made by a trained door systems technician.

14.ALWAYSdisconnect electric power to garage door openerBEFOREmaking any repairs or removing covers.

15SAVETHESEINSTRUCTIONS..

Using Your Garage Door Opener

Your Security÷ ® opener and hand-held remote control have been factory-set to a matching code which changes with each use, randomly accessing over 100 billion new codes. Your opener will operate with up to eight Security4 ,_ remote controls and one Security÷ ® Keyless Entry System. If you purchase a new remote, or if you wish to deactivate any remote, follow the instructions in the Programming section.

Activate your opener with any of the following:

The hand-held Remote Control: Hold the large push button down until the door starts to move.

The wall-mounted Door Control: Hold the push button or bar down until the door starts to move.

The Keyless Entry (See Accessories): If provided with your garage door opener, it must be programmed before use. See Programming.

When the opener is activated (with the safety reversing sensor correctly installed and aligned)

1.If open, the door will close. If closed, it wilt open.

2.If closing, the door will reverse.

3.If opening, the door will stop.

4.If the door has been stopped in a partially open position, it will close.

5.If obstructed while closing, the door will reverse, if the obstruction interrupts the sensor beam, the opener lights will blink for five seconds.

6.If obstructed while opening, the door will stop.

7.If fully open, the door will not close when the beam is broken. The sensor has no effect in the opening cycle.

If the sensor is not installed, or is misaligned, the door won'tclose from a hand-held remote. However, you can close the door with the Door Control, the Outdoor Key Switch, or Keyless Entry, if you activate them until down travel is complete. If you release them too soon, the door will reverse.

The opener lights will turn on under the following conditions: when the opener is initially plugged in; when power is restored after interruption; when the opener is activated.

Lights will also turn on when someone walks through the open garage door.

They will turn off automatically after 4-1/2 minutes. Bulb size is 75 watts maximum.

3O

Image 30
Contents Garage Door Opener Abridor DE Puerta DE Cochera Table of Contents Preparing your garage door Tools neededSectional Door One-Piece Door Sectional Door Installation Sectional Door InstallationsPlanning ONE-PIECE Door Installations ONE-PIECE Door Without TrackONE-PIECE Door with Track Carton Inventory Assembly Hardware Hardware InventoryAssembly Step Assemble the Rail & Install the lolleyInstall the Idler Pulley Fasten the Rail to the Motor UnitInstall the Chain/Cable RexScrewsInstallation Tighten the ChainTrolley Installation Step Determine the Header Bracket LocationInstall the Header Bracket Wall Header Bracket InstallationCeiling Header Bracket Installation Attach the Rail to the Header Bracket Position the Opener Sectional Door or ONE-PIECEDOOR with TrackHang the Opener HiddenInstall the Door Control Outside Keylock Accessory ConnectionsInstall the Light Attach the Emergency Release Rope and HandleElectrical Requirements Install The Protector System Important Information about Safety Reversing SensorFacing the door from inside the garage Installing the Brackets Wall installationMounting and Wiring the Safety Sensors Aligning the Safety SensorsTroubleshooting the Safety Sensors Fasten the Door Bracket Sectional DoorsUre ONE-PIECE Doors Screws not provided to fasten the bracket to the doorConnect Door Arm to Trolley Sectional Doors onlyAdjustment procedures, Figure Closed door adjustment decrease Down travel limitALL ONE-PIECE Doors Travel cycle after each adjustment Adjustment StepAdjust the UP and Down Travel Limits HOW and When to Adjust the LimitsAdjust the Force HOW and When to Adjust the ForcesTest the Down close force Test The Protector System Test the Safety Reversal SystemAdjust TestUsing Your Garage Door Opener OperationActivate your opener with any of the following Lockout position Using Wall.Mounted To Open the Door Manually ControlDisconnect the Trolley TrolleTwice a Year Care of Your OpenerOnce a Month Once a YearMy remotes will not activate the door Having a PROBLEM?My lights will not turn off when door is open My door reverses for no apparent reasonSymptom LED is not lit on door control Not glow steadyTom Motor unit doesnt operate Programming To Add or Reprogram a Hand.held Remote ControlUsing the Learn Button Using the Premium Control Console To Erase All Codes From Motor Unit MemoryUsing the Learn Button Using the Premium Control Console Add, Reprogram Or Change Keyless Entry PINRepair Parts Rail Assembly Parts Installation PartsDescription MotorUnitAsmblyPas ExtemsiOn Bracketsi 139.53786 AccessoriesWA R RJ 139i53709DO Gleaan BrakeRevisi6n de los Simbolos y Trminos de Seguridad Preparaci6n de !,,1 puerta de su cochera Herramientas necesariasPlanificaci6n Instalacin CON UNA Puerta SeccionalPlanificaci6n continUa INSTALACI6N CON Puertas DE UNA Sola PiezaInventario de la Caja de Cart6n Inventario de Piezas Rcrascadtrol TORNILLERfA Y Piezas Para LA InstalacinMonte el Riel e instale el Trole Fije el Riel a la Unidad del Motor Instale la Polea LocaIii!iii!iii!iii!iii!iii!iii!iii!iii!iii!iii!iii!iiTEIA Instale la Cadena y CableInstruccion ES IM Portantes Para Apriete la CadenaINSTALACION, Paso Determine d6nde va a instalar La M6nsula del CabezalInstale la Mnsula del Cabezal Coloque el Riel en la Mnsula del Cabezal Coloque el Abridor en Posici6n Retire la espuma de embalajeCuelgue el Abridor Instale la Unidad de Control de la Puerta Conexiones pare la Unidad de Control ExteriorColoque la Cuerda y la Manija de Emergencia Instale la Luce¢!A Requisitos para la Instalaci6n ElctricaInstale La Sistema de Protecci6n Si se instalay se alinea oorreotamente, el sensordelEstos sensoresse deben instalaren el interiorde la Instatacl6n en el p!$o Flgura SiguientesInstatacl6n en la pazd Flgura 2 y La ilustraci6nCOMe Alinear LOS Sensores DE Seguridad INSTALACION, Paso 1 Fije la Mnsula de la PuertaPuertas DE UNA Sola Pieza Conecte el Brazo de la Puerta al Trole FlguraProcedlmlento de ajuste, Flgura Conecte e! braze de la puerta a! troteAjuste el Limite del Recorrido Hacia Arriba y Hacia Abajo St la puerta no se abre per !o menos 1.5 m 5 piesAjuste la Fuerza Pruebe la fuerza de/recorrldo Hacia Arriba abrlrPruebe el Sistema de Retroceso de Seguridad Pruebe La Sistema de Protecci6nAjuste Para reducir el riesgo de lesiones graves o la muerte C6mo Usar su Abridor de Puerta de CocheraC6mo Usar la Unidad de Control de Pared C6mo Abrir la Puerta ManualmenteMarius ERTErt¢i AscondicionesSl Tiene Algun Problema Tabla de Diagn6stico Sfntoma E! LED del control de ta puerta no se enclendeSuelte los botones cuandolab lucos C6mo Agrogar o Reprogramar Un Control Remoto ManualCoro Usar LA Consola DE Control Premium Controles Remotos FuncionesEnoendida por 30 segundos Para porter un PiN temporal$61o estan dlsponlbles a travd$ de Reface!ones y Servlclo SearsMY-HOME