d. Remove top hinge covers. (A below)
3. Connecting Water Supply
WARNING
To avoid electrical shock which can cause severe personal injury or death, green ground wire must remain attached to hinge.
e.Electronic and Dispenser Models
Unplug top hinge wire connectors. Do not remove green ground wire from hinge. Carefully lift and remove top hinges. Do not disturb position of hinge shims. (B)
WARNING
To avoid electrical shock which can cause severe personal injury or death, disconnect power to refrigerator before connecting water supply. After connecting water supply, connect power.
Caution
A
C
D
E
B
F
G
To avoid property damage, observe the following:
•Confirm water pressure to water valve is between 20 and 100 pounds per square inch.
•If water filter will be installed, water pressure to water valve must be a minimum of 35 pounds per square inch.
•Tighten nut by hand to avoid cross threading. Finish tightening nuts with pliers and wrenches. Do not overtighten.
•Check for water leaks and correct if necessary before returning refrigerator to normal location and 24 hours after connecting.
C. | Hinge cover | F. | Wire connectors |
D. | Door hinge screws | G. | Green ground wire |
E.Top hinge Top hinge removal
f.Remove doors.
Caution
To avoid property damage, protect soft vinyl or other flooring with cardboard, rugs, or other protective material when moving refrigerator.
g.Slide appliance cart under side of refrigerator. Wrap refrigerator with blanket or pad. Thread cart strap around refrigerator and tighten. Do not overtighten strap. Move refrigerator in front of final location.
h.Rehang doors by reversing steps
2.Install Water Filtration Cartridge (some models)
a.Remove bypass cartridge from water filter head in rear right corner of refrigerator section. Twist cartridge counterclockwise 1/4 turn and pull down to remove. Save bypass for use at a later date.
b.See Water Filtration System Installation and Operating Instructions provided with water filter cartridge for filter installation and operation.
Important
•Before connecting water supply, contact a plumber to connect copper tubing to household plumbing in compliance with local codes and ordinances.
•A
Materials Required
1/4" (6 mm) flexible copper tubing. Length of copper tubing must reach from water supply connection plus an additional 8' (2 m) for service loop behind refrigerator.
Procedure
1.Remove plastic cap from water valve inlet port. Place brass nut and brass sleeve on copper tubing. Insert copper tubing into water valve inlet port. Connect brass nut on copper tubing to water valve inlet port. Confirm copper tubing is secure by pulling on copper tubing.