Rotel RA-05 owner manual Preamp Outputs u, Speaker Outputs io Speaker Selector Switch

Page 7

Input Signal Connections

[See Figure 2.]

NOTE: To prevent loud noises that neither you nor your speakers will appreciate, make sure the system is turned off when you make any signal connections.

Phono Input r and

Ground Connection e

Plug the cable from the turntable into the ap- propriate left and right phono inputs. If the turntable has a “ground” wire connect it to the screw terminal to the left of the Phono inputs. It will help prevent hum and noise.

Line Level Inputs t

The CD, Tuner, and Aux inputs of the RA-05 are “line level” inputs. These are for connect- ing components such as CD players, Hi Fi or NICAM Stereo video cassette recorders, tuners, Laser Disc players or the analog output from a CD ROM drive.

The Left and Right channels are labeled and should be connected to the corresponding channels of the source component. The Left connectors are white, the Right connectors are red. Use high quality RCA cables for connecting input source components to the RA-05. Ask your authorized Rotel dealer for advice about cables.

Recorder Connections y

[See Figure 2.]

The Tape inputs and outputs can be connected to any record/playback device that accepts standard line level analog input and output signals. Typically that will be a conventional tape recorder.

When connecting a recorder to the RA-05 remember that the outputs of the recorder must be connected to the tape inputs of the RA-05. Similarly the tape outputs of the RA-05 must be connected to the inputs of the recorder. As with other sources be sure to connect the Left and Right channels of each device to the proper channels on the associated components. Use high quality connecting cables to prevent loss of sound quality.

7

NOTE: The Tape Outputs are not affected by the Volume, Balance or Tone controls. They receive a fixed level signal.

Preamp Outputs u

The RA-05 has a set of preamp outputs. The signal from the source selected with the Func- tion Selector is always available from these outputs. Typically these outputs are used to provide a signal to another integrated ampli- fier or power amplifier, which is used to drive remote speakers

NOTE: Changes to the settings of the Vol- ume, Balance or Tone controls affect the sig- nal from the Preamp Outputs.

Speaker Outputs io Speaker Selector Switch 7

[See Figure 2.]

The RA-05 has two sets of speaker outputs, labeled “A” i and “B” o. The speaker outputs are controlled by the switch 7 on the front panel.

Speaker Selection

If only one set of speakers will be used at any given time, the speakers may have an imped- ance as low as 4 ohms. If there are times when both the A and B speakers will be used, all the speakers should have an impedance of 8 ohms or more. Speaker impedance ratings are less than precise. In practice, very few loudspeakers will present any problems for the RA-05. See your authorized Rotel dealer if you have any questions.

Speaker Wire Selection

Use insulated two-conductor stranded wire to connect the RA-05 to the speakers. The size and quality of the wire can have an audible effect on the performance of the system. Stan- dard speaker wire will work, but can result in lower output or diminished bass response, particularly over longer distances. In general, heavier wire will improve the sound. For best performance, you may want to consider special high-quality speaker cables. Your authorized Rotel dealer can help in the selection of cables for your system.

English

Polarity and Phasing

The polarity – the positive/negative orientation of the connections – for every speaker and amplifier connection must be consistent so all the speakers will be in phase. If the polarity of one connection is reversed, bass output will be very weak and stereo imaging degraded. All wire is marked so you can identify the two conductors. There may be ribs or a stripe on the insulation of one conductor. The wire may have clear insulation with different color conductors (copper and silver). There may be polarity indications printed on the insulation. Identify the positive and negative conductors and be consistent with every speaker and amplifier connection.

Speaker Connection

Turn off all the components in the system before connecting the speakers. The RA-05 has color- coded binding post type speaker connectors on the back panel (except in European Community countries where their use is not permitted). These connectors accept bare wire, connector lugs, or dual banana type connectors.

Route the wire from the RA-05 to the speakers. Give yourself enough slack so you can move the components to allow access to the speaker connectors. If you are using dual banana plugs, connect them to the wires and then plug into the backs of the binding posts. The thumbscrews of the binding posts should be screwed in all the way (clockwise).

If you are using terminal lugs, connect them to the wires. If you are attaching bare wires directly to the binding posts, separate the wire conductors and strip the insulation from the end of each conductor. Be careful not to cut into the wire strands. Unscrew (turn counterclockwise) the binding post thumbscrews. Place the connec- tor lug or wire around the binding post shaft. Turn the thumbscrews clockwise to clamp the connector lug or wire firmly in place.

NOTE: Be sure there are no loose wire strands that could touch adjacent wires or connectors.

Image 7
Contents RA-05 Important Safety Instructions Органы управления и разъемы EnglishBranchement RA-05 Stereo Integrated AmplifierBefore making connections Éteignez cet appareil et le systèmeAbout Rotel ContentsGetting Started AC Power and Control Preamp Outputs u Speaker Outputs io Speaker Selector SwitchIR Inputs and Outputs Phones OutputMedia Player Audio ControlsSpecifications TroubleshootingVolt Trigger Outlet \ Instructions importantes concernant la sécurité Spécifications Sommaire Au sujet de RotelPour démarrer FrançaisAlimentation secteur et mise sous tension Branchement des signaux en entréeSorties enceintes acoustiques io et sélecteur des enceintes Prise casqueSorties préamplificateur u Branchements de l’enregistreur yEntrées et sorties IR infrarouge Commandes audioPrise de commutation Trigger 12 V \ Problèmes de fonctionnement ’indicateur Power de mise sous tension ne s’allume pasRemplacement du fusible SpécificationsWichtige Sicherheitshinweise Deutsch Die Firma RotelFernbedienung RR-AT94 InhaltsverzeichnisNetzspannung und Bedienung EingangssignalanschlüsseTAPE-Anschlüsse y KopfhörerbuchsePreamp-Ausgänge u IR-Ein- und -Ausgänge BedienelementeMedia Player-Anschluss 12V Trigger OUT- Anschlüsse \ Bei StörungenSchutzschaltung Technische DatenImportanti informazioni di Sicurezza Italiano Per cominciareIndice Alcune parole sulla RotelAlimentazione AC e comandi Collegamenti del registratore y Uscite per i diffusori i e o e selettore dei diffusoriUscite del preamplificatore u Controlli audio Uscita cuffiaIngressi ed uscite IR Uscita Trigger 12V \ CaratteristicheCircuito di Protezione Información Importantes Relacionadas con la Seguridad Español Acerca de RotelPara Empezar ContenidoAlimentación y Control Conexiones de EntradaRA-05Amplificador Integrado Estereofónico Salidas Preamplificadas u Conexiones para Grabador ySalida de Auriculares Controles de AudioEntradas y Salidas de Rayos Infrarrojos Toma para Señal de Disparo de 12 V \ Problemas y Posibles SolucionesCaracterísticas Técnicas Circuitería de ProtecciónWaarschuwing Aan de slag met de RA-05 InhoudWij van Rotel De RR-AT94 afstandsbedieningRA-05Geïntegreerde Stereo Versterker Het aansluiten op het lichtnetDe luidsprekeruitgangen io en luidspreker- keuzeschakelaar De hoofdtelefoonuitgangDe verbindingen maken met een opname/ weergave apparaat y De voorversterker- uitgangen uDe infrarood in- en uitgangen De bedieningsorganenDe extra weergave-ingang Media Player De 12V Trigger uitgang \ Wat te doen bij problemen?Technische gegevens Het beveiligingscircuitViktig säkerhetsinformation Innehåll Om RotelIntroduktion RR-AT94 FjärrkontrollStröm och strömfunktioner Anslutningar för insignalerHörlursutgång Förstegsutgångar uHögtalarutgångar io Högtalarväljare Säkringskrets Volts styrsignaler \Och utgångar för IR-signaler LjudkontrollerSäkringsbyte Strömindikatorn Power lyser inteFelsökning 45SvenskaВажные инструкции по безопасности Компании Rotel СодержаниеПервые шаги Пульт RR-AT94См. рис Входы усилителяВходы левого и правого каналов помечены Положением переключателя 7на передней панели Выходы предусилителя uВход и выход ИК ДУ Регуляторы звукаНормальное положение этого регулятора 12-В триггерные выходы \ Схемы защитыТехнические характеристики Диагностика и устранение неполадокUSA