Rotel RA-05 owner manual Troubleshooting, Specifications, Volt Trigger Outlet

Page 9

12 Volt Trigger Outlet \

Some audio components can be turned on automatically when they receive a 12V turn on “signal”. The two12V Trigger Outputs of the RA-05 provide the required signal. Connect compatible components to the RA-05 with a conventional 3.5mm miniplug cable. When the RA-05 is in Standby mode, the trigger signal is interupted, so the components controlled by it are turned off.

Protection Indicator 3

The RA-05 has both thermal and over-current protection circuitry that protects the amplifier against damage in the event of extreme or faulty operating conditions. The protection circuits are independent of the audio signal and have no impact on sonic performance. Instead, the protection circuits monitor the temperature of the output devices and shut down the amplifier if temperatures exceed safe limits.

9

Troubleshooting

Most difficulties in audio systems are the result of incorrect connections, or improper control settings. If you encounter problems, isolate the area of the difficulty, check the control settings, determine the cause of the fault and make the necessary changes. If you are unable to get sound from the RA-05 refer to the suggestions for the following conditions:

Power Indicator Is Not Lit

The Power Indicator should be lit whenever the RA-05 is plugged into the wall power outlet and the Power Switch is pushed in. If it does not light, test the power outlet with another electrical device, such as a lamp. Be sure the power outlet being used is not controlled by a switch that has been turned off.

English

Fuse Replacement

If another electrical device works when plugged into the power outlet, but the Power Indicator of the RA-05 does not light when plugged into the same outlet and the Power Switch is pushed in, it indicates that the internal power fuse may have blown. If you believe this has happened, contact your authorized Rotel dealer to get the fuse replaced.

No Sound

Check the signal source to see if it is function- ing properly. Make sure the cables from the signal source to the RA-05 inputs are connected properly. Be sure the Listening Selector is set to the proper input. Check the wiring between the RA-05 and the speakers.

Most likely, you will never see this protection circuitry in action. However, should a faulty condition arise, the amplifier will stop playing and the LED indicator on the front panel will light up.

If this happens, turn the amplifier off. Let it cool down for several minutes, and attempt to identify and correct the problem that caused the protection circuitry to engage. When you turn the amplifier back on, the protection circuit will automatically reset and the indicator LED should go out.

In most cases, the protection circuitry activates because of a fault condition such as shorted speaker wires, or inadequate ventilation lead- ing to an overheating condition. In very rare cases, highly reactive or extremely low imped- ance speaker loads could cause the protection circuit to engage.

If the protection circuitry triggers repeatedly and you are unable to isolate and correct the faulty condition, contact your authorized Rotel dealer for assistance in troubleshooting.

Specifications

Continuous Power Output

40 watts/ch

(20-20 kHz, < 0.03%, 8 ohms)

 

Total Harmonic Distortion (20Hz-20kHz)

< 0.03% at rated power, 1/2 power or 1 watt

Intermodulation Distortion (60 Hz : 7 kHz, 4:1)

< 0.03% at rated power, 1/2 power or 1 watt

Frequency Response

 

Phono Input

20Hz-15kHz, ±0.3dB

Line Level Inputs

10Hz-40kHz, ±1dB

Damping Factor (20-20,000 Hz, 8 ohms)

180

Input Sensitivity / Impedance

 

Phono Input

2.5mV / 47 kOhms

Line Level Inputs

150 mV / 24 kOhms

Input Overload

 

Phono Input

180mV

Line Level Inputs

5V

Premp Output / Impedance

1V / 470 Ohms

Tone Controls - Bass / Treble

±6 dB at 100Hz / 10kHz

Signal to Noise Ratio (IHF “A” weighted)

 

Phono Input

80 dB

Line Level Inputs

100 dB

Power Requirements

 

USA Version

120 Volts, 60 Hz

European Version

230 Volts, 50 Hz

Power Consumption

220 Watts

Dimensions (W x H x D)

437 x 72 x 342 mm

 

17 1/8 x 27/8 x 131/2

Panel Height

60 mm / 23/8

Weight (net)

5.9 kg, 13 lbs.

All specifications are accurate at the time of printing.

Rotel reserves the right to make improvements without notice.

Image 9
Contents RA-05 Important Safety Instructions Органы управления и разъемы EnglishBefore making connections RA-05 Stereo Integrated AmplifierÉteignez cet appareil et le système BranchementContents About RotelGetting Started AC Power and Control Preamp Outputs u Speaker Outputs io Speaker Selector SwitchMedia Player Phones OutputAudio Controls IR Inputs and OutputsTroubleshooting SpecificationsVolt Trigger Outlet \ Instructions importantes concernant la sécurité Pour démarrer Sommaire Au sujet de RotelFrançais SpécificationsAlimentation secteur et mise sous tension Branchement des signaux en entréeSorties préamplificateur u Prise casqueBranchements de l’enregistreur y Sorties enceintes acoustiques io et sélecteur des enceintesCommandes audio Entrées et sorties IR infrarougePrise de commutation Trigger 12 V \ Remplacement du fusible ’indicateur Power de mise sous tension ne s’allume pasSpécifications Problèmes de fonctionnementWichtige Sicherheitshinweise Fernbedienung RR-AT94 Die Firma RotelInhaltsverzeichnis DeutschNetzspannung und Bedienung EingangssignalanschlüsseKopfhörerbuchse TAPE-Anschlüsse yPreamp-Ausgänge u Bedienelemente IR-Ein- und -AusgängeMedia Player-Anschluss Schutzschaltung Bei StörungenTechnische Daten 12V Trigger OUT- Anschlüsse \Importanti informazioni di Sicurezza Indice Per cominciareAlcune parole sulla Rotel ItalianoAlimentazione AC e comandi Uscite per i diffusori i e o e selettore dei diffusori Collegamenti del registratore yUscite del preamplificatore u Uscita cuffia Controlli audioIngressi ed uscite IR Caratteristiche Uscita Trigger 12V \Circuito di Protezione Información Importantes Relacionadas con la Seguridad Para Empezar Acerca de RotelContenido EspañolConexiones de Entrada Alimentación y ControlRA-05Amplificador Integrado Estereofónico Salidas Preamplificadas u Conexiones para Grabador yControles de Audio Salida de AuricularesEntradas y Salidas de Rayos Infrarrojos Características Técnicas Problemas y Posibles SolucionesCircuitería de Protección Toma para Señal de Disparo de 12 V \Waarschuwing Wij van Rotel InhoudDe RR-AT94 afstandsbediening Aan de slag met de RA-05RA-05Geïntegreerde Stereo Versterker Het aansluiten op het lichtnetDe verbindingen maken met een opname/ weergave apparaat y De hoofdtelefoonuitgangDe voorversterker- uitgangen u De luidsprekeruitgangen io en luidspreker- keuzeschakelaarDe bedieningsorganen De infrarood in- en uitgangenDe extra weergave-ingang Media Player Technische gegevens Wat te doen bij problemen?Het beveiligingscircuit De 12V Trigger uitgang \Viktig säkerhetsinformation Introduktion Om RotelRR-AT94 Fjärrkontroll InnehållStröm och strömfunktioner Anslutningar för insignalerFörstegsutgångar u HörlursutgångHögtalarutgångar io Högtalarväljare Och utgångar för IR-signaler Volts styrsignaler \Ljudkontroller SäkringskretsFelsökning Strömindikatorn Power lyser inte45Svenska SäkringsbyteВажные инструкции по безопасности Первые шаги СодержаниеПульт RR-AT94 Компании RotelВходы усилителя См. рисВходы левого и правого каналов помечены Положением переключателя 7на передней панели Выходы предусилителя uРегуляторы звука Вход и выход ИК ДУНормальное положение этого регулятора Технические характеристики Схемы защитыДиагностика и устранение неполадок 12-В триггерные выходы \USA