INSTALLATION
Connecting the transformer
Take the following into consideration when planning where to place the transformer:
• Close to the charging station • Protection from rain
• Protection from direct sunlight
If the transformer is connected to an electrical socket outdoors, this must be approved for outdoor use.
The low voltage cable for the transformer is 10 metres long, and may not be shortened or extended. A longer low voltage cable is available as optional accessory. Please contact your dealer for more information.
It is not allowed to connect the transformer directly to the charging station. The low voltage cable must always be used.
IMPORTANT INFORMATION
The low voltage cable must not under any circumstances be shortened or extended.
It is possible to let the low voltage cable cross the working area. The low voltage cable must be stapled down or buried, and the cutting height should be such that the blades on the blade disc can never come in contact with the low voltage cable.
Make sure the low voltage cable is laid along the ground and secured with pegs 75 cm apart. The cable must lie close to the ground so as not to be cut before the grass roots have grown over it.
IMPORTANT INFORMATION
Place the low voltage cable so that the blades on the blade disc can never come in contact with it.
The transformer must be placed where it is well ventilated and is not exposed to direct sunlight. The transformer must be placed under a roof.
It is recommended to use an earth
The transformer must be mounted on a vertical surface, such as a wall or a fence. Screw the transformer in place using the two mounting eyelets. No screws are supplied. Select screws suitable for the material in question.
min 30cm/12”
English - 18