Example: Fiber Link Through Patch Panels

Figure 2-2 illustrates two ONline Concentrators are separated by 1700 meters of fiber cable with two patch panels in between. If we use 50/125 fiber cable, the optical power budget according to Table 2-3 is 10.0 dB.

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Patch 1700 meters Patch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Panel

Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connectors

Connectors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.7 Km Fiber Cable

 

 

8.5 dB loss worst case using 5 dB/Km loss fiber cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Two ST Patch Panel

 

 

1.5 dB loss worst case

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Path Loss

 

 

10.0

dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2-2. 1700 Meter Fiber Link Through Two Patch Panels

Total path loss in this example is 10 dB. Because the overall optical power budget for 50/125 cable is 10.0 dB, this leaves 0 dB to spare.

In addition, the received optical power is on the outer edge of the specification. As defined in Table 2-3, the peak received power range for 50/125 cable is -29.5 dB. Adding the path loss of 10.0 dB to -19.5 dB equals -29.5.

This may cause the 10BASE-FL Module Port Status LED to signal a no light condition. If a no light condition occurs, you must reduce the optical path loss by shortening the cable or by eliminating some of the optical connectors.

2 - 12 ONline Ethernet 10BASE-FL Installation and Operation Guide