Example: Connecting a Thin Ethernet (10BASE2) Segment

Figure 2-9 shows a typical Thin Ethernet segment connected to an ONline Concentrator through an IEEE 802.3 Repeater

.

 

 

 

10BASE-FL Module

 

 

 

 

 

 

 

 

10BASE-FL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Backbone

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10BASE-FL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transceiver

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

51 01T-FL

 

 

IEEE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Repeater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500 m

 

 

 

 

10BASE-T Module

 

 

 

 

50

 

m

 

 

 

 

 

 

 

 

Transceiver

Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coaxial

Transceiver

A

185m

Thin Ethernet

10BASE-TTransceiver (5101T-TP)

 

 

 

 

100 m

 

 

B

10BASE-FL Module

 

 

 

 

 

 

Figure 2-9. Thin Ethernet Segment Connecting to ONline Using an IEEE Repeater

To determine if the configuration in Figure 2-9 meets Ethernet distance limitations for transceivers A and B:

1.Use 4200 meters as the maximum network diameter as defined by the 802.3 specification.

2.Subtract the fiber equivalent distance of 420 m for the signal externally entering the 10BASE-T Module from Transceiver B and 230 meters for the signal exiting the 10BASE-FL Module within the same concentrator. (Ethernet Rule 4)

3.Subtract the fiber equivalent distance of 560 meters for the signal externally entering the 10BASE-FL Module in the top concentrator, and internally exiting a different port on the same 10BASE-FL Module.

4.Subtract the fiber equivalent distance (800 m) of the IEEE Repeater. (Ethernet Rule 4)

2 - 26 ONline Ethernet 10BASE-FL Installation and Operation Guide

Page 48
Image 48
3Com 5104M-FL1 installation and operation guide Example Connecting a Thin Ethernet 10BASE2 Segment, Ieee