3Com XLPCI manual Troubleshooting Hubs with Crossover Cable, Crossover cable

Models: XLPCI

1 74
Download 74 pages 2.84 Kb
Page 62
Image 62

C-2APPENDIX C: TROUBLESHOOTING NETWORK CONNECTION PROBLEMS

Troubleshooting Hubs with Crossover Cable

A crossover cable can be used to identify the type of failure when hub performance or connectivity is in question.

1Connect a file server and a client PC back to back with a crossover cable to verify that the NIC and network operating system are properly configured.

2To make a crossover cable, connect TD+ to RD+ and TD– to RD–.

The cable performs the crossover that is usually performed by the hub. Figure C-1 shows the pinouts for the

crossover cable:

.

12345678

 

Straight-through

 

 

Crossover

 

 

 

 

 

 

10BASE-T cable

 

 

10BASE-T cable

 

1

 

1

TD+ 1

1

TD+

 

2

 

2

TD

2

2

TD

 

3

 

3

RD+ 3

3

RD+

 

4

 

4

 

4

4

 

 

 

 

5

 

5

RD

5

5

RD

 

6

 

6

6

6

 

7

 

7

 

7

7

 

 

 

 

8

 

8

 

8

8

 

 

 

 

Figure C-1Straight-through and Crossover Cable Pinouts

If the file server and client PC function together as a small network, then either the existing cabling or the hub is failing.

When a crossover cable is used, the LED on the NIC functions differently than it would under normal operating conditions. For example, with a correct crossover connection, the LED lights, whereas with a straight-through connection, the LED does not light. If you make a crossover cable and the polarity is mismatched (that is, TD+ to RD– instead of TD+ to RD+), the LED blinks.

Page 62
Image 62
3Com XLPCI manual Troubleshooting Hubs with Crossover Cable, Crossover cable