7DQGEHUJ'DWD 6&6,&RPPDQGV
 7DQGEHUJ'/73URGXFW0DQXDO
/2*6(/(&7&RPPDQG&KFRQWLQXHG
/2*3$5$0(7(56
Bit
Byte
76543210
0 -1
(MSB)
Parameter Code
(LSB)
2 DU DS TSD ETC TMC RsvdLP
3 Parameter Length
4 - 7
(MSB)
Parameter Value
(LSB)
)LJXUH±/RJ3DUDPHWHUV)RUPDW
)LHOG1DPH 'HVFULSWLRQ
Parameter Code Parameter Codes supported for the READ/WRITE error counter
pages are as follows:
3DUDPHWHU&RGH 'HVFULSWLRQV
00h Errors corrected with substantial delays
01h Errors corrected with possible delays
02h Total rewrites or rereads
03h Total errors corrected
04h Total times correction algorithm processed
05h Total bytes processed
06h Total uncorrected errors
8000h Vendor Unique
1RWH Parameter codes 00h, 01h, and 04h always have a value of
0. Parameter value for 05h is 8 bytes; the parameter length is
set to 8.