7DQGEHUJ'DWD 6&6,&RPPDQGV

7DQGEHUJ'/73URGXFW0DQXDO 

02'(6(/(&7&RPPDQGKKFRQWLQXHG
 '$7$&2035(66,213$*()K

The Data Compression page specifies parameters for the control of data

compression. This page allows the user to turn the tape drives compressed format

on and off independently of the tape mediums position.

Bit
Byte
76543210
0 Reserved Page Code (0Fh)
1 Page Length (0Eh)
2 DCE DCC
(1)
Reserved
3 DDE
(1)
RED
(00)
Reserved
4 - 7
(MSB)
Compression Algorithm
(10) (LSB)
8 - 11
(MSB)
Decompression Algorithm
(10) (LSB)
12 - 15 Reserved

)LJXUH±'DWD&RPSUHVVLRQ3DJH)RUPDW'HVFULSWRU²'DWD)RUPDW