Chapter 5: Configuration

Maintenance Setup

There are three Maintenance Setup options: Auto Traps, ADLP Address, and Port Mode.

Auto Traps

Auto Traps is for use with Port Mode=ATEL. The ISU 512 monitors and re- ports alarms for network failures or degrading performance conditions. The ISU 512 can be configured to generate protocol traps autonomously by select- ing Enable. To disable protocol traps, select Disable. The ISU 512 sends a trap for the following conditions:

ISDN #1, #2, #3, #4 Link Down ISDN #1, #2, #3, #4 Link Up

Data Call connected at unexpected data rate. (less than expected)

ADLP Address

Select ADLP Address to enter an ADLP address to the ISU 512 as required for use with ADTRAN T-Watch Management Software. This address is used when the ISU 512 maintenance port is programmed for ADLP or ATEL mode.

Port Mode

Port Mode allows the unit to be set for VT 100 terminal or ADLP/ATEL mode for use with ADTRAN T-Watch or ADVISOR SNMP software packages. Se- lecting ADLP allows the ISU 512 to use the ADTRAN Data Link Protocol which is used to send T-Watch commands between the PC and the ISU 512. Selecting ATEL allows the ISU 512 to use ADLP/ATEL protocols to commu- nicate with the ADTRAN ADVISOR SNMP software. Select Terminal Mode to allow access of the ISU 512 using a VT 100 terminal. Use the following menu path to access Maintenance Setup for Dial Line operation:

3=CONFIG 1=Netw. options

1=Dial Line 9=Maint. Setup

1=Auto Traps 2=ADLP Address 3=Port Mode

61202.086L1-1

ISU 512 User Manual

37

Page 53
Image 53
ADTRAN ISU 512 user manual Maintenance Setup, Auto Traps, Adlp Address, Port Mode