Chapter 3: Installation
Software Update
There are two methods available for updating ISU 512 software. The local method involves using the Chain In port and is described in this section. The remote method involves transmitting smart dial strings over a
The ISU 512 contains Flash memory allowing the software to be updated using the Chain In port. The ISU 512 software can be updated using any PC with an
Ensure the terminal software package has flow control turned off.
1. Power the ISU 512 Off.
2.Connect the PC to the ISU 512 using an
3.Start the communication package, supporting XMODEM protocol, on the PC. Set for Connect Local if necessary.
4.Set the COM port for 38400, 8, 1, n and no flow control.
5.Start the XMODEM protocol and transfer the .bin file to the ISU 512. XMODEM should come
6.Power On the ISU 512 while holding the Up Arrow. Holding the Up Ar- row during self test initiates the software update.
Do not power Off the unit during the loading process. After the load is complete the ISU 512 restarts itself. If power is lost during the software load, repeat the procedure from the beginning.
It may be necessary to set the communications software to Connect Local, which sets the session up to ignore carrier detect on the
ISU 512 User Manual | 13 |