Chapter 7: Troubleshooting
F.Ensure nothing else is bridged across the ISDN line pair.
G.With a minimum of extra wiring, try connecting to the line pair at the point where service provider's wiring ends.
H.With the ISU 512 connected to the ISDN line and powered up, contact and inform the service provider's repair group that your ISDN basic rate line has a Physical Layer 1 problem. Request the ISDN line be checked.
IF THE DISPLAY READS TEI1
If the ISU 512 reads TEI1, then the ISU 512 is physically connected to the local telephone service provider but is unable to establish Logical Layer 2. The problem is in one or more of the following places:
•The ISU 512 software setup
•The telephone service provider's software setup
•Hardware configuration if the line is extended from the switch
To isolate the problem, use the following procedure:
1.Ensure the ISU 512 is set up for the correct switch type by selecting CON- FIG, Netw. options, Dial Line, and Switch type.
2.Ensure ISDN line quality is satisfactory by checking for near- and
NEBE/FEBE count may indicate a
If the counts are
•The ISU 512 software setup
•The ISU 512 hardware
•CPE wiring
•Wiring from the telephone service provider
•Hardware of the telephone service provider
•Software setup of the telephone service provider
ISU 512 User Manual | 63 |