Appendix B: Log Messages
NOT end2end ISDN level 4
The path that the call was routed over is not ISDN from
Power Up - last down cause: <reason> level 0 (displayed as level 1 after the unit is reset)
This is the <reason> for the last reset. Most are caused by internal errors. Pos- sible reasons are:
Bus Error - Bad address occurred on the internal bus Kernel error - General operating system error
No SBCs - Mail resources used up or lost Router stack error - Fatal error in protocol stack
general panic - general error no rip - rip tasks could not start
out of memory - out of available memory out of TCP ports - all TCP ports are used up unknown error - unknown fatal error has occurred
Set timer error - Cannot set real time clock
Software Watch Dog Reset - Software watchdog was not updated
Probe: all ports busy level 3
All ports were busy when it was time to probe. An attempt will be made on the next probe interval.
Probe failed level 2
An attempt to connect to a probe site failed.
Probing <name> level 4
The Express L128/L128T is making an outgoing call to the destination speci- fied by the description in the Connection List in order to get an update on routes.
POTS call bump level 4
The Express L128/L128T has dropped bandwidth on an existing data call so that a POTS call can be connected.
Express L128/L128T User Manual | 133 |