ADTRAN L128T user manual NOT end2end ISDN level

Models: L128T L128

1 200
Download 200 pages 61.82 Kb
Page 150
Image 150
NOT end2end ISDN level 4

Appendix B: Log Messages

NOT end2end ISDN level 4

The path that the call was routed over is not ISDN from end-to-end. This is a warning and is most often seen for POTS calls.

Power Up - last down cause: <reason> level 0 (displayed as level 1 after the unit is reset)

This is the <reason> for the last reset. Most are caused by internal errors. Pos- sible reasons are:

Bus Error - Bad address occurred on the internal bus Kernel error - General operating system error

No SBCs - Mail resources used up or lost Router stack error - Fatal error in protocol stack

general panic - general error no rip - rip tasks could not start

out of memory - out of available memory out of TCP ports - all TCP ports are used up unknown error - unknown fatal error has occurred

Set timer error - Cannot set real time clock

Software Watch Dog Reset - Software watchdog was not updated

Probe: all ports busy level 3

All ports were busy when it was time to probe. An attempt will be made on the next probe interval.

Probe failed level 2

An attempt to connect to a probe site failed.

Probing <name> level 4

The Express L128/L128T is making an outgoing call to the destination speci- fied by the description in the Connection List in order to get an update on routes.

POTS call bump level 4

The Express L128/L128T has dropped bandwidth on an existing data call so that a POTS call can be connected.

61202.070L1-1

Express L128/L128T User Manual

133

Page 150
Image 150
ADTRAN L128T user manual NOT end2end ISDN level