AC Inverter Drive

Machines equipped with the AC inverter drive require special attention with regard to the operating environment.

An especially dusty or linty environment will require more frequent cleaning of the AC inverter drive cooling fan filter(s) and of the AC inverter drive itself.

Power line fluctuations from sources such as uninterruptible power supplies (UPS) can adversely affect machines equipped with the AC inverter drive. Proper suppression devices should be utilized on the incoming power to the machine to avoid problems.

A clean power supply free from voltage spikes and surges is absolutely essential for machines equipped with the AC inverter drive. Nonlinear inconsistencies (peaks and valleys) in the power supply can cause the AC inverter drive to generate nuisance errors.

If voltage is above 230 Volt for 200 Volt installations or above 440 Volt for 400 Volt installations, a buckboost transformer is recommended. If voltage is above 240 or 480, a buckboost transformer is required.

Sufficient space to perform service procedures and routine preventive maintenance is especially important for machines equipped with the AC inverter drive.

Safety

Misuse

Never use this machine for any purpose other than washing fabric.

Never wash petroleum-soaked rags in the machine. This could result in an explosion.

Never wash machine parts or automotive parts in the machine. This could result in serious damage to the basket.

Never allow children to play on or around this machine. Death or serious injury can result if children become trapped in the machine. Do not leave children unattended while the machine door is open. These cautions apply to animals as well.