Operation

Table 1 (Continued)

Display Interpretations

Display

 

Meaning

Display

Meaning

 

 

 

 

 

STOP

 

Stop button pressed or cycle ended

 

WE-6 Prompts

 

 

 

 

 

S1

 

Supply #1 (Detergent)

°FAR

Temperature in degrees Fahrenheit

 

 

 

 

 

S2

 

Supply #2 (Bleach)

°CEN

Temperature in degrees Centigrade

 

 

 

 

 

S3

 

Supply #3 (Sour)

1DRAIN

One drain capability selected. (This means

 

 

 

 

that a second independent drain controlled by

 

 

 

 

Auxiliarry 2 output is disabled.)

 

 

 

 

 

S4

 

Supply #4 (Softener)

2DRAIN

Second independent drain enabled (via

 

 

 

 

Auxiliary 2 output – precludes control of

S5

 

Supply #5 (Starch/Sizing)

 

 

 

recirculation pump via Auxiliary 2, if

 

 

 

 

TH

 

Controlled temperature fill to high level

 

selected). This should not be confused with

 

 

 

 

the “dual drain” option.

TM

 

Controlled temperature fill to medium level

 

 

 

 

 

 

 

 

 

TL

 

Controlled temperature fill to low level

ADV

Advance (skip steps) feature enabled

 

 

 

 

 

TO

 

Controlled temperature overflow

NO ADV

Advance feature disabled

 

 

 

 

 

WH

 

Warm fill to high level

MANUAL

Manual Mode enabled

 

 

 

 

 

WM

 

Warm fill to medium level

NO MAN

Manual Mode disabled

 

 

 

 

 

WL

 

Warm fill to low level

WET CL

Wet clean function for Auxiliary 1 output

 

 

 

 

(1/2 wash speed) and Auxiliary 2 output

WO

 

Warm fill to overflow level

 

 

 

(recirculation pump) enabled. (Refer to

 

 

 

 

W1

 

Wash 1 (regular reversing)

 

“2DRAIN”.)

 

 

 

 

 

W2

 

Wash 2 (gentle reversing)

NO WCL

Wet clean function for Auxiliary 1 and 2

 

 

 

 

disabled (Auxiliary 1 and 2 are timed

W3

 

Wash 3 (no agitation)

 

 

 

outputs).

 

 

 

 

 

 

 

 

 

W4

 

Wash 4 (medium reversing action)

BAL SW

Balance sensor

 

 

 

 

 

W5

 

Wash 5 (temp.-controlled cool-down)

BAL 1

Balance routine for 1305 inverter drive

 

 

 

 

 

W6

 

Wash 6 (extra low agitation)

BAL 2

Balance routine for 1336 inverter drive for

 

 

 

 

135-pound capacity

W7

 

Wash 7 (no agitation, drain 1 open, no refill)

 

 

 

 

 

 

 

 

 

 

Left dot – poor balance condition

BAL 3

Balance routine for 1336 inverter drive for

 

 

 

 

250-pound capacity

 

Second dot from left – door lock switch

 

 

 

 

 

 

 

 

 

 

Third dot from left – Program Mode

 

 

 

 

 

 

 

 

Fourth dot from left – high level reached

 

 

 

 

 

 

 

 

Fifth dot from left – medium level reached

 

 

 

 

 

 

 

 

Right dot – low level reached

 

 

 

 

 

 

 

F232101

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT