Programming a Supply Step – Models with 8 Supplies

On models equipped with 8 supplies, the WE-6 computer is capable of controlling 8 separate supplies, and up to 31 various combinations of the 8 supplies. Refer to Table 8 for a listing of the energized supply compartments represented by each display code. The supplies are divided into 2 separate banks of 4 supplies each. Supply 5 acts as a switching function between the 2 banks of supplies and is counted as one of the

31 combinations, as it can be programmed alone for special applications.

The LED display will indicate the combination of supply compartments that will energize for that particular supply. For example, when a Supply 3 (first supply bank, third supply signal) is programmed, the display reads “S3nncc”, with “nn” representing the step number and “cc” representing the cycle number. Supply 3 flushes supply compartment 3. When Supply 7 (second supply bank, second supply signal) is selected, the display reads “S7nncc”. Refer to Table 7 for a full explanation of the 8 available supplies.

To program a supply in the first supply bank, follow this procedure:

1.The computer must be in Program Mode and the cycle programming sequence must be ready for the next step.

2.Press the Supply key. The display will read “S-nncc”. Press key 1, 2, 3, or 4, whichever corresponds to the appropriate supply valve to be turned on. If key 4 is pressed, for example, the display will read “S4nncc”.

3.Press the Enter key. The display will read

“M---S”. Now enter the time in minutes and seconds that the supply injection should last.

4.Press the Enter key and go to the next step of the cycle.

Programming

The supplies in the second bank operate in the following manner:

NOTE: To energize the second bank of supplies, press the Supply key and key 5. Supply 5 serves only as a switching function between the first and second supply banks, and is not an actual supply output.

1.The computer must be in Program Mode, and the cycle programming sequence must be ready for the next step.

2.Press the Supply key followed by key 5 to switch from the first supply bank to the second supply bank. The display will read “S5nncc”. Now press key 1, 2, 3, or 4, whichever corresponds to the appropriate supply valve to be turned on. Pressing key 1 will energize the first supply signal of the second supply bank, supply signal 6. The display will read “S6nncc”. Pressing key 2 will energize the second supply signal of the second supply bank, supply signal 7. Pressing key 3 energizes the third supply signal of the second bank, supply signal 8. Pressing key 4 energizes the fourth supply signal of the second bank, supply signal 9.

F232101

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

49