It is possible to change which supply compartments are flushed for a particular supply. For example, a Supply 3 (first supply bank) energizes compartment 3. Suppose that there is a need for compartments 1 and 3 to energize instead. The following procedure would accomplish this:

1.Advance to the supply step to be changed (Supply 3 in this case).

2.The display will read “S3nncc”.

3.Press the Clear/Stop key to clear the programmed supply compartments to be flushed from the WE-6 computer.

4.Press the Supply key and key 3 again.

5.The display will read “S-nncc”.

6.Now press key 1 to program a flush of compartment 1.

7.Press key 3 to program a flush of compartment 3.

8.The display will read “SBnncc”, with B representing the code from Table 8 that corresponds to the energizing of compartments 1 and 3.

NOTE: The order in which key 1 and key 3 are pressed is not important. The computer’s interpretation of the supply compartment combination is not dependent upon the order of entry.

9.Press the Enter key. The display will now read “M---S”. Enter the time in minutes and seconds that the supply injection should last.

10.Press the Enter key and go on to the next step in the cycle.

 

 

 

Programming

 

 

 

Supply Display Codes (5 Supplies)

 

 

 

 

 

 

 

Supply Number

 

Code

 

0 = Supply Off

 

 

X = Supply On

 

 

 

 

 

 

 

5 4 3 2 1

 

 

 

 

 

1

 

0 0 0 0 X

 

 

 

 

 

2

 

0 0 0 X 0

 

 

 

 

 

A

 

0 0 0 X X

 

 

 

 

 

3

 

0 0 X 0 0

 

 

 

 

 

B

 

0 0 X 0 X

One

 

 

 

C

 

0 0 X X 0

 

 

 

 

 

 

Bank

D

 

0 0 X X X

 

 

 

4

 

0 X 0 0 0

Supply

 

 

 

E

 

0 X 0 0 X

 

 

 

 

 

 

 

F

 

0 X 0 X 0

 

 

 

 

 

H

 

0 X 0 X X

 

 

 

 

 

I

 

0 X X 0 0

 

 

 

 

 

J

 

0 X X 0 X

 

 

 

 

 

L

 

0 X X X 0

 

 

 

 

 

M

 

0 X X X X

 

 

 

 

 

5

 

X 0 0 0 0

 

 

 

 

 

6

 

X 0 0 0 X

 

 

 

 

 

7

 

X 0 0 X 0

 

 

 

 

 

N

 

X 0 0 X X

 

 

 

 

 

8

 

X 0 X 0 0

 

 

 

 

Two

O

 

X 0 X 0 X

 

 

 

P

 

X 0 X X 0

Bank

 

 

 

Q

 

X 0 X X X

 

 

 

 

 

 

Supply

9

 

X X 0 0 0

 

 

 

R

 

X X 0 0 X

 

 

 

 

 

 

 

S

 

X X 0 X 0

 

 

 

 

 

T

 

X X 0 X X

 

 

 

 

 

U

 

X X X 0 0

 

 

 

 

 

V

 

X X X 0 X

 

 

 

 

 

W

 

X X X X 0

 

 

 

 

 

X

 

X X X X X

 

 

 

 

 

 

Table 8

F232101

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT