6Electrical Data
6.1Absolute Ratings
The IC is not designed to operate beyond the parameters shown in the following table.
Parameter | Minimum | Maximum | Comments |
|
|
|
|
VDD12[B, A] | 1.7 V |
| |
|
|
|
|
VDD15 | 2.0 V |
| |
|
|
|
|
VDD18, VDDA18 | 2.3 V |
| |
|
|
|
|
VDD33 | 3.6 V |
| |
|
|
|
|
TCASE (Under Bias) |
| 85 ° C |
|
TSTORAGE | 150 ° C |
|
Table 6: Absolute maximum ratings.
6.2Operating Ranges
The IC is designed to provide functional operation if the voltage and temperature parameters are within the limits defined in the following table.
Parameter | Minimum | Typical | Maximum | Units | Comments |
|
|
|
|
|
|
VDD12[B, A] | 1.14 | 1.2 | 1.26 | V |
|
|
|
|
|
|
|
VDD15 | 1.425 | 1.5 | 1.575 | V |
|
|
|
|
|
|
|
VDD18, VDDA18 | 1.71 | 1.8 | 1.89 | V |
|
|
|
|
|
|
|
VDD33 | 3.135 | 3.3 | 3.465 V | V |
|
|
|
|
|
|
|
TCASE (Under Bias) |
|
| 85 | deg C |
|
Table 7: Operating ranges.