![6.4AC Characteristics](/images/new-backgrounds/24962/2496273x1.webp)
24888 Rev 3.03 - July 12, 2004 |
6.4AC Characteristics
See the HyperTransport Technology Electrical Specification for the AC characteristics of link signals. The following table shows AC specification data for clocks.
Symbol | Parameter Description | Min | Max | Units | Comments |
|
|
|
|
|
|
tREF | REFCLK cycle time | 15 | 18 | ns |
|
tCYC | A_PCLK cycle time | 15 |
| ns | Matches REFCLK |
tHIGH | A_PCLK high time | 6 |
| ns |
|
tLOW | A_PCLK low time | 6 |
| ns |
|
tSLEW | A_PCLK slew rate | 1 | 4 | V/ns |
|
Table 12: AC data for clocks.
The following table shows AC specification data for common clock (A_PCLK) operation of AGP signals.
Symbol | Parameter Description | Min | Max | Units | Notes |
|
|
|
|
|
|
tVAL | A_PCLK to signal valid delay | 1 | 5.5 | ns |
|
tON | A_PCLK to signal | 1 | 6 | ns |
|
tOFF | A_PCLK to signal | 1 | 14 | ns |
|
tSU | Signal input setup time to A_PCLK | 6 |
| ns |
|
tH | AGP signal input hold time after A_PCLK | 0 |
| ns |
|
tRF | Signal output rise and fall slew rate | 2 | 3.5 | V/ns |
|
Table 13: AC data for common clock operation of AGP signals.
37