AMX NXD-CV5 Troubleshooting Information Cont, Symptom, Solution, My Modero panel isn’t appearing

Models: NXD-CV5

1 162
Download 162 pages 52.79 Kb
Page 150
Image 150
Troubleshooting Information (Cont.)

Troubleshooting

Troubleshooting Information (Cont.)

Symptom

Solution

 

 

My Modero panel isn’t appearing

• Verify that the System number is the same on both the NetLinx

in my Workspace window.

Workspace window and the System Connection page on the Modero

 

panel.

 

• Verify you have entered the proper NetLinx Master IP and connection

 

methods into the Master Connection section of the System

 

Connection page.

 

 

My Modero panel can’t obtain a

In requesting a DHCP Address, the DHCP Server can take up to a few

DHCP Address

minutes to provide the address.

 

• Verify there is an active Ethernet connection attached to the rear of

 

the Modero before beginning these procedures.

 

• Select Diagnostics > Network Address, from the Main menu and

 

verify the System number.

 

• If the IP Address field is still empty, give the Modero a few minutes to

 

negotiate a DHCP Address and try again.

 

 

My panel is not showing up in the

If you a Virtual Master has already connected to the target panel, the

Virtual Master’s System list of

G4 device retains the information of the previous Virtual Master System

connected devices.

number.

 

• Reboot the panel without the USB cable plugged into the panel.

 

• Configure NetLinx Studio for a Virtual Master connection. Note the

 

System Number used in the Edit Settings window.

 

• Stop communication on the Virtual Master by going to Settings >

 

Stop Communications.

 

• Click Yes to stop communication.

 

• Select the System Number (from the Online Tree tab) and use a right

 

mouse click to select Refresh System. This re-establishes

 

communication with the Virtual Master.

 

Plug-in the mini-USB cable into the corresponding port on the panel.

 

• Wait a few seconds and refresh the system. This re-establishes

 

communication with the Virtual Master. The panel should now appear

 

in the list of available devices.

 

 

My Connection Status button isn’t

"USB Connecting" is displayed when the panel is trying to establish

blinking and it says the USB is

USB communication with the PC (either within the NetLinx Studio or

connecting.

TPDesign4 applications).

 

• Remove the USB connector from the panel and close any AMX

 

applications.

 

• Reboot the panel.

 

• Launch the AMX application and attempt reconnect to the panel.

 

• If using Studio for Virtual Master communication, establish a Virtual

 

Master connection, verify the correct System number, stop

 

communication with the Virtual Master, and then re-establish

 

communication by refreshing the system.

 

• After the panel powers-up, reconnect the USB connector to the

 

panel.

 

• Verify that you have a valid USB connection from within your System

 

Tray.

 

 

144

5" Modero Widescreen Touch Panel

Page 150
Image 150
AMX NXD-CV5 Troubleshooting Information Cont, Symptom, Solution, My Modero panel isn’t appearing, in my Workspace window