AMX NXD-CV5 manual Prepare the panel for communication via an IP

Models: NXD-CV5

1 162
Download 162 pages 52.79 Kb
Page 64
Image 64
Step 2: Prepare the panel for communication via an IP

Upgrading Modero Firmware

8.Click the New button to open the New TCP/IP Settings dialog where you can enter both a previously obtained DHCP or Static IP Address and an associated description for the connection into their respective fields.

9.Place a checkmark within the Automatically Ping the Master Controller to ensure availability radio box to make sure the Master is initially responding online before establishing full communication.

10.Click OK to close the current New TCP/IP Settings dialog and return to the previous TCP/IP Settings dialog where you must locate your new entry within the List of Addresses section.

11.Click the Select button to make that the currently used IP Address communication parameter.

12.Click OK to return to the Communications Settings dialog and place a checkmark within the Authentication Required radio box if your Master has been previously secured with a username/ password.

13.Click on the Authentication Required radio box (if the Master is secured) and then press the User Name and Password button to open the Master Controller User Name and Password dialog.

14.Within this dialog, you must enter a previously configured username and password (with sufficient rights) before being able to successfully connect to the Master.

15.Click OK to save your newly entered information and return to the previous Communication Settings dialog where you must click OK again to begin the communication process to your Master.

If you are currently connected to the assigned Master, a popup asks whether you would want to temporarily stop communication to the Master and apply the new settings.

16.Click Yes to interrupt the current communication from the Master and apply the new settings.

17.Click Reboot (from the Tools > Reboot the Master Controller dialog) and wait for the System Master to reboot. The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait until the STATUS LED is the only LED to blink.

18.Press Done once until the Master Reboot Status field reads *Reboot of System Complete*.

19.Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default System value is one (1).

20.Right-click the associated System number and select Refresh System. This establishes a new connection to the specified System and populates the list with devices on that system. The communication method is then highlighted in green on the bottom of the NetLinx Studio window.

Step 2: Prepare the panel for communication via an IP

1.Press the blue Type field (from the Master Connection section) until the choice cycles to the word Ethernet.

2.Press the blue Mode field until the choice cycles to the word URL.

By selecting URL, the System Number field becomes read-only (grey) because the panel pulls this value directly from the communicating target Master (virtual or not). A Virtual Master system value can be set within the active AMX software applications such as: NetLinx Studio, TPD4, or IREdit.

3.Press the red Master IP/URL field to open a Keyboard and enter the NetLinx Master’s

IP Address (obtained from the Diagnostics - Networking Address dialog of the NetLinx Studio application).

4.Click Done to accept the new value and return to the System Configuration page.

5.Do not alter the Master Port Number value (this is the default value used by NetLinx).

58

5" Modero Widescreen Touch Panel

Page 64
Image 64
AMX NXD-CV5 manual Prepare the panel for communication via an IP