"^" Button Commands (Cont.)

^UNI

Set Unicode text.

For the ^UNI command (%UN and ^BMF command), the Unicode text is sent as ASCII-HEX nibbles.

Syntax:

"'^UNI-<vt addr range>,<button states range>,<unicode text>'"

Variable:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and 2 = On state).

unicode text = Unicode HEX value.

Example:

SEND_COMMAND Panel,"'^UNI-500,1,0041'"

Sets the button’s unicode character to ’A’.

Note: To send the variable text ’A’ in unicode to all states of the variable text button 1, (for which the character code is 0041 Hex), send the following command:

SEND_COMMAND TP,"'^UNI-1,0,0041'"

Note: Unicode is always represented in a HEX value. TPD4 generates (through the Text Enter Box dialog) unicode HEX values. Refer to the TPDesign4 Instruction Manual for more information.