10.Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.

Installing the NXD into drywall using Expansion Clips

Expansion clips are mounted through the three oval holes located along the rim of the NXD-CV5. As the screw is tightened, the clip bends toward the insertion hole and into the wall. This bending creates a "grip" on the wall by either pressing onto the wall or by securing the drywall between the housing and the drywall clip.

The most important thing to remember when mounting the NXD is that the outer frame (Mounting Tabs) must be installed flush against the mounting surface.

Refer to SP-2261-02for detailed installation dimensions (reproduced in FIG. 19).

It is recommended that you cutout the surface slightly smaller than what is outlined in the installation drawings so that you can make any necessary cutout adjustments.

1.Prepare the area by removing any screws or nails from the drywall before beginning the cutout process.

2.Cut out the surface for the NXD Wall Mount unit.

If installing the panel into a pre-existing wall or surface, place and secure the pre-printed

Mounting Template for Flush Mount Drywall Installation (62-2261-10) onto the surface.

Trace the required cutout along the drywall. Refer to the dimensions in FIG. 19 for more information.

It is recommended that the actual cutout opening be slightly smaller than the provided dimensions. This action provides the installer with a margin for error if the opening needs to later be expanded.

Be sure to cut out the three notches along the sides to accommodate the three corresponding drywall expansion clips (included within the Installation Kit).

3.Remove the Faceplate/bezel (A in FIG. 20) from the main NXD unit (B in FIG. 20) by gripping the faceplate and pulling with gentle outward force.

4.Thread the incoming power, RJ-45, Ethernet, USB, and any optional audio/video wiring (from their terminal locations) through the surface opening. Leave enough slack in the wiring to accommodate any re-positioning of the panel.

5.Connect all data and power wiring connectors to their corresponding locations along the left side of the (un-powered) NXD touch panel.

Verify that the terminal end of the power cable is not connected to a power source before plugging in the 2-pin power connector.

The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.