AXIS 2120 User’s Manual

Troubleshooting

55

PINGing Your IP Address

By sending a packet to the specified address and waiting for a reply, the PING utility can determine whether a specific IP address is accessible. It also provides a particularly useful method for confirming addressing conflicts with your AXIS 2120 on the network.

Follow the instructions below in association with Symptoms, Possible Causes and Remedial Actions, on page 56, and run the PING utility to troubleshoot TCP/IP problems on your network:

1.Start a Command window.

2.Type ping x.x.x.x, where x.x.x.x is the IP address of the AXIS 2120.

3.If you recieve the reply destination host unreachable, then the AXIS 2120 is not accessible on your subnet. You must obtain a new IP address and reinstall the unit.

If this does not solve the problem, disconnect the AXIS 2120 from the network and run the PING command again. See the table below for an interpretation of the results.

PING Reply

Interpretation and recommendation

 

 

Reply from <IP address>: bytes = 32;

The IP address is already used and cannot be used again. You must obtain a

time = 10 ms

new IP address.

Request timed out

This IP address is not used and is available for use with your AXIS 2120. If

 

you set the IP address previously, the installation might not have been

 

performed correctly. In this case, reinstall the unit. Also check all cabling.

 

 

Page 55
Image 55
Axis Communications 2120 user manual PINGing Your IP Address, Ping Reply Interpretation and recommendation, New IP address