Belkin PureAV Hybrid AVU1500 UPS

Using Your AVU1500 with a

Home Automation System (optional)

The PresentStatus in Power Status is a collection item that includes:

VoltageOutOfRange: The input voltage is lower or beyond the normal range. The UPS transfers to backup mode and supplies the output power from battery.

Buck: The input power is suppressing to normal range.

Boost: The input power is boosting to normal range.

Overload: The loading beyond the rating power.

Standby: The UPS is in standby mode, which mans the UPS is not turned on.

OverTemperature: Over temperature.

InternalFail: UPS general fail indication.

BuzzerSilence: Indicates to support buzzer enable/disable control item.

Beeper: To indicate the UPS buzzer is silent or alarm.

AVU Special Features (Page 0x86)

Report ID #

Usage (usage ID)

Byte #

Unit

Comment

 

 

 

 

 

 

110

Stage 1 Battery Threshold (0x29)

1

%

R/W

 

 

 

 

 

 

 

111

Stage 2 Battery Threshold (0x29)

1

%

R/W

 

 

 

 

 

 

 

112

Stage 3 Battery Threshold (0x29)

1

%

R/W

 

 

 

 

 

 

 

113

Stage 1 Load Current (0x31)

1

Amps

R

 

 

 

 

 

 

 

114

Stage 2 Load Current (0x31)

1

Amps

R

 

 

 

 

 

 

 

115

Stage 3 Load Current (0x31)

1

Amps

R

 

 

 

 

 

 

 

117

Site Wiring Fault (0xFC)

1

 

R

 

 

 

 

 

 

 

118

Site Ground Fault (0xFB)

1

 

R

 

 

 

 

 

 

 

119

Stage 1 Remaining Time (0xFA)

2

Sec

R

 

 

 

 

 

 

 

120

Stage 2 Remaining Time (0xFA)

2

Sec

R

 

 

 

 

 

 

 

121

Stage 3 Remaining Time (0xFA)

2

Sec

R

 

 

 

 

 

 

 

122

Shutdown Override (0xF9)

1

 

R/W

IN/Feature*

 

 

 

 

 

 

123

IR Shutdown Code Known (0xF8)

1

 

R

IN/Feature*

 

 

 

 

 

 

124

IR Shutdown Code Broadcast at

1

Stage

R

 

Beginning of Stage N (0xF7)

Number

 

 

 

 

 

 

 

 

 

 

 

85

Source Change (0xF6)

1

 

 

IN*

 

 

 

 

 

 

86

Stage 1 startup/shutdown (0xF5)

1

 

R

IN/Feature*

 

 

 

 

 

 

87

Stage 2 startup/shutdown (0xF5)

1

 

R

IN/Feature*

 

 

 

 

 

 

88

Stage 3 startup/shutdown (0xF5)

1

 

R

IN/Feature*

 

 

 

 

 

 

89

Overload (0xF2)

1

 

 

IN*

 

 

 

 

 

 

90

Battery Fully Charged (0xF1)

1

 

R

IN/Feature*

 

 

 

 

 

 

91

Battery Needs Replacement

1

 

 

IN*

(0xF0)

 

 

 

 

 

 

 

 

 

 

 

 

 

92

Power Off Notification (0xFD)

1

 

 

IN*

 

 

 

 

 

 

IN* indicates this item is interrupt only, IN/Feature means this item supports both interrupt and feature.