Belkin PureAV Hybrid AVU1500 UPS
Using Your AVU1500 with a
Home Automation System (optional)
•The PresentStatus in Power Status is a collection item that includes:
•VoltageOutOfRange: The input voltage is lower or beyond the normal range. The UPS transfers to backup mode and supplies the output power from battery.
•Buck: The input power is suppressing to normal range.
•Boost: The input power is boosting to normal range.
•Overload: The loading beyond the rating power.
•Standby: The UPS is in standby mode, which mans the UPS is not turned on.
•OverTemperature: Over temperature.
•InternalFail: UPS general fail indication.
•BuzzerSilence: Indicates to support buzzer enable/disable control item.
•Beeper: To indicate the UPS buzzer is silent or alarm.
AVU Special Features (Page 0x86)
Report ID # | Usage (usage ID) | Byte # | Unit | Comment | |
|
|
|
|
|
|
110 | Stage 1 Battery Threshold (0x29) | 1 | % | R/W |
|
|
|
|
|
|
|
111 | Stage 2 Battery Threshold (0x29) | 1 | % | R/W |
|
|
|
|
|
|
|
112 | Stage 3 Battery Threshold (0x29) | 1 | % | R/W |
|
|
|
|
|
|
|
113 | Stage 1 Load Current (0x31) | 1 | Amps | R |
|
|
|
|
|
|
|
114 | Stage 2 Load Current (0x31) | 1 | Amps | R |
|
|
|
|
|
|
|
115 | Stage 3 Load Current (0x31) | 1 | Amps | R |
|
|
|
|
|
|
|
117 | Site Wiring Fault (0xFC) | 1 |
| R |
|
|
|
|
|
|
|
118 | Site Ground Fault (0xFB) | 1 |
| R |
|
|
|
|
|
|
|
119 | Stage 1 Remaining Time (0xFA) | 2 | Sec | R |
|
|
|
|
|
|
|
120 | Stage 2 Remaining Time (0xFA) | 2 | Sec | R |
|
|
|
|
|
|
|
121 | Stage 3 Remaining Time (0xFA) | 2 | Sec | R |
|
|
|
|
|
|
|
122 | Shutdown Override (0xF9) | 1 |
| R/W | IN/Feature* |
|
|
|
|
|
|
123 | IR Shutdown Code Known (0xF8) | 1 |
| R | IN/Feature* |
|
|
|
|
|
|
124 | IR Shutdown Code Broadcast at | 1 | Stage | R |
|
Beginning of Stage N (0xF7) | Number |
| |||
|
|
|
| ||
|
|
|
|
|
|
85 | Source Change (0xF6) | 1 |
|
| IN* |
|
|
|
|
|
|
86 | Stage 1 startup/shutdown (0xF5) | 1 |
| R | IN/Feature* |
|
|
|
|
|
|
87 | Stage 2 startup/shutdown (0xF5) | 1 |
| R | IN/Feature* |
|
|
|
|
|
|
88 | Stage 3 startup/shutdown (0xF5) | 1 |
| R | IN/Feature* |
|
|
|
|
|
|
89 | Overload (0xF2) | 1 |
|
| IN* |
|
|
|
|
|
|
90 | Battery Fully Charged (0xF1) | 1 |
| R | IN/Feature* |
|
|
|
|
|
|
91 | Battery Needs Replacement | 1 |
|
| IN* |
(0xF0) |
|
| |||
|
|
|
|
| |
|
|
|
|
|
|
92 | Power Off Notification (0xFD) | 1 |
|
| IN* |
|
|
|
|
|
|
IN* indicates this item is interrupt only, IN/Feature means this item supports both interrupt and feature.
59