Using Your AVU1500 with a

Home Automation System (optional)

Stage 1 Battery Threshold: default 90%, range from Stage 2 to 100%.

Stage 2 Battery Threshold: default 50%, range from Stage 3 to Stage 1.

Stage 3 Battery Threshold: default 0%, range from 0% to Stage 2.

Site Wiring Fault: 0: Wiring OK, 1: Wiring Fault.

Site Ground Fault: 0: Ground OK, 1: Ground Fault.

Shutdown Override: 1: Disable, 2: Enable.

IR Shutdown Code Known: 0: Unknown, 1: Learned.

Source Change: 0: Backup ¬ AC, 1: AC ¬ Backup.

Stage 1 startup/shutdown: 0: Startup, 1: Shutdown.

Stage 2 startup/shutdown: 0: Startup, 1: Shutdown.

Stage 3 startup/shutdown: 0: Startup, 1: Shutdown.

Overload: 0: Not overload, 1: Overload.

Battery Fully Charged: 0: Not fully charged, 1: Fully charged.

Battery Need Replacement: 0: Battery OK, 1: Battery need replacement.

Power Off: 0: UPS power on, 1: UPS power off.