Belkin PureAV Hybrid AVU1500 UPS

Using Your AVU1500 with a

Home Automation System (optional)

Check Sum

Sum the bytes from “Header” to “Data”. Overflow ignored.

Notification

AVU models have the ability to send UPS data to PC regardless of any pending polling commands from computer.

Power Configuration Controls (UsagePage=0x86)

Report ID#

 

Usage (usage ID)

Byte #

Unit

Comment

 

 

 

 

 

 

 

 

 

1

}

ConfigVoltage

(0x40)

1

Volt

R

 

 

 

 

 

 

 

 

2

}

ConfigFrequency (0x42)

1

Hertz

R

 

 

 

 

 

 

 

 

3

}

ConfigApparentPower (0x43)

2

VA

R

 

 

 

 

 

 

 

 

4

}

ConfigBatteryVolt (0x44)

2

Volt

R

 

 

 

 

 

 

 

ConfigVoltage:

Nominal value of the voltage.

 

ConfigFrequency:

Nominal value of the frequency.

 

ConfigApparentPower: Nominal value of the apparent power.

ConfigBatteryVoltage: Nominal value of the battery voltage.

Power Device Identification (UsagePage=0x86)

Report ID #

Usage (usage ID)

Byte #

Unit

Comment

 

 

 

 

 

13

}Model String Index (0x75)

1

 

R

 

 

 

 

 

14

}Model String Offset (0x76)

1

 

R

 

 

 

 

 

15

}UPSType (0x7C)

1

 

R

 

 

 

 

 

Model String Index: Index of a string descriptor describing model names string. The UPS Model String may contain several model names, each name is separated by a “/”. If this command comes from the RS232, then UPS returns the Model String rather than Index.

Model String Offset: Offset of the UPS model name in the model names string.

UPSType:

• Low 4 bits Result

0:On-Line

1:Off-Line

2:Line-Interactive

3:Simple On-Line

4:Simple Off-Line

5:Simple Line-Interactive

• High 4 bits Result

Indicates the firmware version

55

Page 58
Image 58