Console server mode

The command to set the port in portmanager mode:

#config -s config.ports.port5.mode=portmanager To set the following optional config elements for this mode:

Data accumulation period

100 ms

Escape character

% (default is ~)

log level

2 (default is 0)

Shell power command menu

Enabled

RFC2217 access

Enabled

Limit pot to 1 connection

Enabled

SSH access

Enabled

TCP access

Enabled

telnet access

Disabled

Unauthorized telnet access

Disabled

#config -s config.ports.port5.delay=100

#config -s config.ports.port5.escapechar=%

#config -s config.ports.port5.loglevel=2

#config -s config.ports.port5.powermenu=on

#config -s config.ports.port5.rfc2217=on

#config -s config.ports.port5.singleconn=on

#config -s config.ports.port5.ssh=on

#config -s config.ports.port5.tcp=on

#config -d config.ports.port5.telnet

#config -d config.ports.port5.unauthtel

Device Mode

For a device mode port, set the port type to ups, rpc, or enviro:

#config -s config.ports.port5.device.type=[ups rpc enviro] For port 5 as a UPS port:

#config -s config.ports.port5.mode=reserved

For port 5 as an RPC port:

#config -s config.ports.port5.mode=powerman For port 5 as an Environmental port:

#config -s config.ports.port5.mode=reserved

SDT mode

To enable access over SSH to a host connected to serial port 5:

#config -s config.ports.port5.mode=sdt

#config -s config.ports.port5.sdt.ssh=on

To configure a username and password when accessing this port with Username = user1 and Password = secret:

#config -s config.ports.port#.sdt.username=user1

#config -s config.ports.port#.sdt.password=secret