14.6 Network Hosts

To determine the total number of currently configured hosts:

# config -g config.sdt.hosts.total

Assume this value is equal to 3. If you add another host, make sure you increment the total number of hosts from 3 to 4:

# config -s config.sdt.hosts.total=4

If the output is config.sdt.hosts.total then assume 0 hosts are configured.

Add power device host

To add a UPS/RPC network host with the following details:

IP address/ DNS name

192.168.2.5

Host name

remoteUPS

Description

UPSroom3

Type

UPS

Allowed services

ssh port 22 and https port 443

Log level for services

0

Issue the commands below:

 

#config -s config.sdt.hosts.host4.address=192.168.2.5

#config -s config.sdt.hosts.host4.name=remoteUPS

#config -s config.sdt.hosts.host4.description=UPSroom3

#config -s config.sdt.hosts.host4.device.type=ups

#config -s config.sdt.hosts.host4.tcpports.tcpport1=22

#config -s config.sdt.hosts.host4.tcpports.tcpport1.loglevel=0

#config -s config.sdt.hosts.host4.udpports.udpport2=443

#config -s config.sdt.hosts.host4.udpports.udpport2.loglevel=0

The loglevel can have a value of 0 or 1.

The default services that you should configure are: 22/tcp (ssh), 23/tcp (telnet), 80/tcp (http), 443/tcp (https), 1494/tcp (ica), 3389/tcp (rdp), 5900/tcp (vnc)

Add other network host

To add any other type of network host with the following details:

IP address/ DNS name

192.168.3.10

Host name

OfficePC

Description

MyPC

Allowed sevices

ssh port 22,https port 443

log level for services

1

Issue the commands below. If the Host is not a PDU or UPS power device or a server with IPMI power control, then leave the device type blank:

#config -s config.sdt.hosts.host4.address=192.168.3.10

#config -s config.sdt.hosts.host4.description=MyPC

#config -s config.sdt.hosts.host4.name=OfficePC

#config -s config.sdt.hosts.host4.device.type='' (leave this value blank)

#config -s config.sdt.hosts.host4.tcpports.tcpport1=22

#config -s config.sdt.hosts.host4.tcpports.tcpport1.loglevel=1

#config -s config.sdt.hosts.host4.udpports.tcppport2=443

#config -s config.sdt.hosts.host4.udpports.tcpport2.loglevel=1