D1260/D1260B Owner's Manual Part II: System Commands - WALK TEST ? (COMMAND + 4 + 4)

4.Your system displays event summary lines and point text in this order:

a.fire alarm summary line

b.point text for each fire alarm event

c.alarm summary line

d.point text for each alarm event

e.fire trouble summary line

f.point text for each fire trouble event

g.trouble summary line

h.point text for each trouble event.

5.Press NEXT> to scroll through the events.

If there are no events to view, There are currently no events in memory displays.

6.You can return to idle text at any time by pressing Exit> soft key.

Upon initiation, the walk test will test the burglary bell pattern on the bell output and ring the keypad burglary bell for 2 seconds. The AC will be disabled for 4 minutes in order to test the system’s battery power. If the battery cannot maintain the system for the 4-minute period, the keypad will appear to go dead. If your keypads are programmed to be supervised, the main alarm panel will beep intermittently during this 4- minute period. If this happens, contact your security company. At the end of the 4-minute period, AC is returned to the system and the panel restores. To test individual detection devices, simply activate sensors and open protected doors and windows one-at-a-time. As each detection device is faulted, the Keypad emits a brief tone and the display indicates for 60 seconds that the point has been tested. This verifies that each detection device is working properly.

Using Walk Test:

1.The display shows disarmed idle text.

2.Press the COMMAND key. The display shows *System Command*.

WALK TEST ? (COMMAND + 4 + 4)

Walk Test

 

Description

 

Use this function to test keypads, detection devices,

3. Press the 4 key and then the 4 key.

and sounders (both interior and exterior) to be certain

 

they function properly. You can review untested points

 

at your keypad to help pinpoint any problems.

 

You cannot arm your system while in the walk test

 

mode, and no alarm reports are sent to your security

 

company unless a 24-hour point is activated (such as

 

fire or panic). A Walk Test Start Report may be

 

programmed to be sent to your security company.

 

Bosch Security Systems 9/04 50410D

25